System Overview

Consumption Power

NO

ITEM

CH1(+5V)

CH2(+24V)

CH3(+24VS)

System

 

 

 

 

 

 

1

Stand-By

0.2A

0.07A

0.07 A

AVG : 100 Wh

 

 

 

 

 

 

2

PRINTING

1.0A

0.5A

1.0 A

AVG 350 Wh

 

 

 

 

 

 

3

Sleep-Mode

0.2A

0.02A

0.03A

AVG : 10 Wh

 

 

 

 

 

 

Length of Power Cord : 183050mm

Power Switch: Use

Feature

-Insulating Resistance: 100 or more (at DC 500V)

-Insulating revisiting pressure: Must be no problem within 1 min. (at 1,000V-LV / 1,500Vac-HV,10mA)

-Leaking Current: under 3.5mA

-Running Current: under 40A PEAK (AT 25, COLD START)

under 60A PEAK (In other conditions)

-Rising Time: within 2Sec

-Falling Time: over 20ms

-Surge : Bi-Wave 3kV(2) - Normal, 6KV(12) - Common

Environment Condition

-Operating Temperature Range: 0 ~ 40

-Maintaining Temperature Range: -25 ~ 85

-Preserving Humidity Condition: 30% ~ 90% RH

-Operating Atmospheric Pressure Range: 1atm

EMI Requirement: CISPR, FCC, CE, MIC

Safety Requirement: IEC950 UL1950, CSA950, C-UL, Semko, CB, CCC(CCIB),GOST, EPA, Power Save

Samsung Electronics

Service Manual 3-17

Page 33
Image 33
Samsung SCX-4200 manual CH1+5V CH2+24V CH3+24VS System, Printing