Troubleshooting
6.2.3 Abnormal noise
•Description There is noise from the Platen when copying.
| Check and Cause |
| Solution |
|
|
|
|
1. | Check the Scan Motor and gesr. | 1. | Check for correct assembly of gear and motor. |
|
|
| Ensure no parts are fouling and there are no foreign |
|
|
| objects in the mechanism or scanner path. Replace |
|
|
| any worn parts |
2. | Check the Motor Driver on Driver PBA. |
|
|
|
| 2. | Replace the main PBA. |
|
|
|
|
6.2.4 Defective Image Quality
•Description The copied image is excessively light or dark
| Check and Cause | Solution |
1. | Check shading profile. | 1. Redo shading profile in the tech mode. |
2. | Check the gap between original and scanner | 2. A gap of more than 0.5 mm can cause a blurred |
| glass. | image. Ensure cover close correctly. Replace as |
|
| necessary. |
3. Check printing quality.
3. See "Print" troubleshooting.
| Service Manual | |
Samsung Electronics |
| |
|
|