Alarm Detection Setup

Off : Sensor does not operate.

N.O(Normal Open) Sensor : Sensor remains open all the time and if closed, an alarm will be issued. (A Contact)

N.C(Normal Close) Sensor : Sensor remains closed all the time and if open, an alarm will be issued. ( B Contact)

Cam

Sets a camera that will synchronize with the current sensor. The default value is currently set to the sensor number. A sensor shall be synchronized with at least a camera. Multi-selection is possible.

Alarm-out

Sets the Alarm-Out when Alarm Sensor sounds.

5 Alarm Outs are supported un the present.

Choose an alarm-out that you want to synchronize with the current sensor. Multi-selection is possible.

Beep-Out

Sets the Alarm-Out Duration. Alarm-Out continues for the set value. Off / 3sec / 5sec / 10sec / 20sec / 30sec

5-22

Page 69
Image 69
Samsung SHR-2042P, SHR-2040PX, SHR-2040P/XEC manual Alarm Detection Setup, Alarm-out, Beep-Out