5.3. Sequence Setting

ƒMemorize: Manual operations for minimum 120 seconds after executing this function are memorized into the internal memory. Nevertheless, the memorizing time becomes different depending on the PTZ operation. OVER mark will finish this function.

 

If the operation range is limited using Pan Limit

Note

and Tilt Limit, only the operations within the limited

range are memorized.

 

 

 

 

 

 

Press the OSD key to stop the internal memory to

Note

continue saving.

 

 

5.3.6. Auto Run

If there is no controller operation by the user for a certain time, the sequence operation designated by the user will be executed.

ƒMode:

-OFF : Auto Run will be cancelled.

-Preset : Auto Run in the corresponding Preset number

-Swing : Auto Run in the corresponding Swing mode

-Group : Auto Run in the corresponding Group number

-Tour : Auto Run in the corresponding Tour number

-Trace : Auto Run in the corresponding Trace number

-A. Pan : 350° Auto Run in Pan direction

Auto Pan Speed: Pan operation in the speed designated by the user.

Tilt Angle: The tilt angle set up by the user is kept.

85