5.3. Sequence Setting

is the moving speed (01-64step). DWL is the stop time (00- 120sec). Press the Execution key in the location with selection mark to finish the setting process.

-Execute : Swing surveillance is executed. Stop key designates this function.

-Clear : Data in the Swing function is deleted.

5.3.3. Group SEQ

Group SEQ: Sequence surveillance can be executed and set up and data can be deleted. Up to 6 groups can be registered.

ƒSetting : Preset position for swing is selected by clicking the mouse and confirmed with the Execution key. SPD is the moving speed (01~64 step). DWL is the stop time (00~120sec). Press the Execution key in the location with selection mark to finish the setting process.

ƒExecute : Swing surveillance can be executed. Stop key will stop this function.

ƒClear : Swing data can be deleted.

5.3.4. Tour SEQ

Group surveillance can be executed and set up and data can be deleted.