Chapter 4 Controlling the Monitor

Change the mode of the registered monitor

To change the mode of the registered monitor, select a mode with the pull-down menu button under the IP address of the target monitor and then click Set button.

Mode

Operation

 

 

Control

Controlling the monitor

Both control

Controlling and displaying pictures

Visual control

Displaying the pictures

OFF

Excluding from the multi-control

Delete

Deleting from the multi-control

*The multi control item is not changed during using the network viewer function. It is not available with the light mode.

Status

If some of the registered monitors are disabled by some reasons (such as disconnecting the power source, dis- connecting the LAN cable, disconnecting from the net- work), control changes will continue to be effective for the monitors that are still active. At the same time, the deactivated monitors are excluded from the multi-con- trol. The status of the registered monitors are indicated under the monitor name. See the table below for status

indications.

Status

 

Status

Description

 

 

(blank)

The monitor is connected to the network correctly

No connect

The monitor may not be connected to the network. Please check the connection

 

and network configuration of this monitor.

PIN code error

The PIN code is incorrect. The PIN code for the multi-controlled monitors must be

File Error

the same. Change the PIN code of this monitor to the common PIN code.

Not displaying the images. Check if this monitor is using the Network Capture func-

 

tion or Network Viewer function individually, or in the standby mode.

* The network unit updates the status at the time when the multi-control function was executed.

If the multi-controlled monitor is in the standby mode, any change is not effective except timer setting.

Cannot register, delete or change the multi-control setting during using the network viewer func- tion.