Sanyo POA-LN02 owner manual Network Communication operation and change of state, Preparation

Models: POA-LN02

1 116
Download 116 pages 60.29 Kb
Page 78
Image 78

Chapter 5 Network Capture

Network Communication operation and change of state

Network Communication can be used under the environment which one or more com- puters are connected to the monitor via the network.

Preparation

Launch the Network Capture 3 software on the target computer ( p.66). Set the monitor in the standby or turning on. Check IP address of the target computer is registered in the connection list ( p.72).

On the Communication

Operation on the Main PC

 

 

 

Operation on the Sub PC

 

 

 

 

 

Frame

The icon on the task bar is activated to

 

Frame

 

 

1Executing the command "Start Communication".

 

 

 

let users know that the captured image is

 

 

 

 

 

 

 

now serving.

 

 

 

 

The capture editing window appears on the

 

 

 

 

 

 

 

screen. The icon on the task bar is activated.

 

R

 

1 Executing the command "Start Editing".

 

 

B

 

 

 

 

The capture image on the Main PC

 

 

 

 

 

 

 

appears on the screen.

 

 

 

 

2Editing the capture image using with the tools.

 

 

 

The editing information on the Main PC is

 

 

 

 

The editing information is automatically

 

R

 

 

 

B

 

transferred to the Sub PC.

 

 

 

reflected on the Sub PC.

 

 

 

 

 

 

 

 

 

 

 

 

3 Releasing the editing authority.

 

 

The color of authority status frame chang-

 

 

 

 

G

 

 

 

G

 

The color of authority status frame changes green.

 

 

 

es green.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Acquiring the authority.

 

 

 

 

The color of authority status frame changes blue.

 

B

 

The color of authority status frame chang-

 

 

R

 

 

 

 

 

es red.

 

 

 

 

 

 

 

 

 

 

 

 

The editing information on the Sub PC is

 

 

 

3 Editing the captured image using with the

 

 

 

 

 

 

 

tools.

 

 

 

 

 

B

 

 

 

R

 

reflected on the Main PC.

 

 

The editing information is automatically

 

 

 

 

 

 

 

transferred to the target PC.

 

 

 

 

 

 

 

 

4 Releasing the editing authority.

 

 

 

 

The color of authority status frame changes green.

 

G

 

The color of authority status frame chang-

 

 

G

 

 

 

 

 

es green.

 

 

 

 

 

 

 

 

 

 

 

 

4 Acquiring the authority.

 

 

The color of authority status frame chang-

 

 

 

 

R

 

 

 

B

 

The color of authority status frame changes red.

 

 

 

es blue.

 

 

 

 

 

 

 

 

 

 

 

 

 

5 Repeat steps 2, 3 if required.

 

 

 

5 Repeat steps 2 to 4 if required.

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Executing the command "Capture transfer".

 

 

 

A new captured screen image appears on

 

 

 

 

Updating the editing window with a new

 

R

 

 

 

B

 

captured screen image.

 

 

 

the editing window.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 Repeat steps 2 to 5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 Ending the communication.

 

 

 

The capture editing window disappears.

 

 

 

 

 

R

 

 

 

 

 

The capture editing window disappears.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

78

The monitor displays the edited captured image on the screen when the input mode of the moni- tor is set "Network".

The command "Save Communication" can be executed in any of the mode even if not having the authority.

The arrow () shows a response to the command executed.

The execution of the command "End Communication" or "End Editing" on the Sub PC has no effect on the other target computers.

Page 78
Image 78
Sanyo POA-LN02 owner manual Network Communication operation and change of state, Preparation, On the Communication