Indoor Unit SAP-K127RAX

Control PCB

Part No.

Controls

Control Circuit Fuse

Remote Control Unit

Fan

CR-K127GAX

Microprocessor

250V 3.15A

RCS-7S2E-G

 

Type

 

 

Cross-Flow

 

Q'ty ... Dia. and Length

 

mm

1 ... D102 / L637

 

 

 

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

AC Motor

 

Model ... Q'ty

 

 

IBH-884-066B ... 1

 

No. of Poles

 

 

4

 

Rough Measure RPM (Cool)

 

 

1,300

 

Nominal Output

 

W

12.5

 

Coil Resistance

 

Ohm

BRN-WHT : 234

 

(Ambient Temp. 20 °C)

 

 

PNK (RED)-WHT : 209

 

Safety Device Type

 

 

Thermal fuse

 

 

Operating Temp.

Open

°C

130

 

 

 

Close

 

-

 

Run Capacitor (on controller PCB)

 

Micro F

1.5

 

 

 

 

VAC

450

 

 

 

 

 

 

Flap Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Stepping Motor

 

Model

 

 

24BYJ48-916

 

Rating

 

 

DC 12V

 

Coil Resistance

 

Ohm

Each Pair of Terminal : 200 +/- 7%

 

(Ambient Temp. 25 °C)

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

 

2

 

Fin Pitch

 

mm

1.1

 

Face Area

 

m2

0.162