Indoor Unit SAP-K127RAX 
Control PCB
Part No.
Controls
Control Circuit Fuse
Remote Control Unit
Fan
Microprocessor
250V 3.15A
| 
 | Type | 
 | 
 | ||
| 
 | Q'ty ... Dia. and Length | 
 | mm | 1 ... D102 / L637 | |
| 
 | 
 | 
 | 
 | 
 | |
| Fan Motor | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Type | 
 | 
 | AC Motor | |
| 
 | Model ... Q'ty | 
 | 
 | ||
| 
 | No. of Poles | 
 | 
 | 4 | |
| 
 | Rough Measure RPM (Cool) | 
 | 
 | 1,300 | |
| 
 | Nominal Output | 
 | W | 12.5 | |
| 
 | Coil Resistance | 
 | Ohm | ||
| 
 | (Ambient Temp. 20 °C) | 
 | 
 | PNK  | |
| 
 | Safety Device Type | 
 | 
 | Thermal fuse | |
| 
 | 
 | Operating Temp. | Open | °C | 130 | 
| 
 | 
 | 
 | Close | 
 | - | 
| 
 | Run Capacitor (on controller PCB) | 
 | Micro F | 1.5 | |
| 
 | 
 | 
 | 
 | VAC | 450 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Flap Motor | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Type | 
 | 
 | Stepping Motor | |
| 
 | Model | 
 | 
 | ||
| 
 | Rating | 
 | 
 | DC 12V | |
| 
 | Coil Resistance | 
 | Ohm | Each Pair of Terminal : 200 +/- 7% | |
| 
 | (Ambient Temp. 25 °C) | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | |
| Heat Exchanger Coil | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Coil | 
 | 
 | Aluminum Plate Fin / Copper Tube | |
| 
 | Rows | 
 | 
 | 2 | |
| 
 | Fin Pitch | 
 | mm | 1.1 | |
| 
 | Face Area | 
 | m2 | 0.162 | |
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11