Indoor Unit SAP-K127RAX
Control PCB
Part No.
Controls
Control Circuit Fuse
Remote Control Unit
Fan
Microprocessor
250V 3.15A
| Type |
|
| ||
| Q'ty ... Dia. and Length |
| mm | 1 ... D102 / L637 | |
|
|
|
|
| |
Fan Motor |
|
|
| ||
|
|
|
|
|
|
| Type |
|
| AC Motor | |
| Model ... Q'ty |
|
| ||
| No. of Poles |
|
| 4 | |
| Rough Measure RPM (Cool) |
|
| 1,300 | |
| Nominal Output |
| W | 12.5 | |
| Coil Resistance |
| Ohm | ||
| (Ambient Temp. 20 °C) |
|
| PNK | |
| Safety Device Type |
|
| Thermal fuse | |
|
| Operating Temp. | Open | °C | 130 |
|
|
| Close |
| - |
| Run Capacitor (on controller PCB) |
| Micro F | 1.5 | |
|
|
|
| VAC | 450 |
|
|
|
|
|
|
Flap Motor |
|
|
| ||
|
|
|
|
|
|
| Type |
|
| Stepping Motor | |
| Model |
|
| ||
| Rating |
|
| DC 12V | |
| Coil Resistance |
| Ohm | Each Pair of Terminal : 200 +/- 7% | |
| (Ambient Temp. 25 °C) |
|
|
| |
|
|
|
|
| |
Heat Exchanger Coil |
|
|
| ||
|
|
|
|
|
|
| Coil |
|
| Aluminum Plate Fin / Copper Tube | |
| Rows |
|
| 2 | |
| Fin Pitch |
| mm | 1.1 | |
| Face Area |
| m2 | 0.162 |
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
11