Sanyo SAP-K77RAX, Sanyo Split System Air Conditoner V Single Phase 50 Hz, Rating Capacity

Models: Sanyo Split System Air Conditoner SAP-K77RAX

1 68
Download 68 pages 41.42 Kb
Page 28
Image 28

Indoor Unit SAP-K127RAX

Outdoor Unit SAP-C127RAX

230 V Single Phase 50 Hz

 

RATING CAPACITY

3.55 kW

 

 

 

 

 

 

AIR FLOW RATE

 

460 m3/h

 

 

 

 

 

 

EVAPORATOR

 

 

 

CONDENSER

 

 

 

 

ENT. TEMP. oC

 

 

OUTDOOR AMBIENT TEMP. oC

 

 

 

W.B.

D.B.

 

 

20

25

30

35

40

43

 

 

 

 

 

TC

3.58

3.42

3.27

3.11

2.92

2.69

 

 

 

 

 

CM

0.92

1.00

1.07

1.15

1.33

1.51

 

 

 

21

 

SHC

2.34

2.25

2.16

2.08

1.98

1.86

 

 

15

23

 

SHC

2.57

2.49

2.40

2.31

2.21

2.10

 

 

 

25

 

SHC

2.81

2.72

2.64

2.55

2.45

2.33

 

 

 

27

 

SHC

3.05

2.96

2.87

2.79

2.69

2.57

 

 

 

29

 

SHC

3.29

3.20

3.11

3.03

2.92

2.69

 

 

 

31

 

SHC

3.52

3.42

3.27

3.11

2.92

2.69

 

 

 

 

 

TC

3.84

3.67

3.50

3.34

3.14

2.89

 

 

 

 

 

CM

0.95

1.03

1.10

1.18

1.36

1.54

 

 

 

21

 

SHC

2.10

2.01

1.92

1.83

1.74

1.61

 

 

17

23

 

SHC

2.33

2.24

2.16

2.07

1.97

1.85

 

 

 

25

 

SHC

2.57

2.48

2.40

2.31

2.21

2.09

 

 

 

27

 

SHC

2.81

2.72

2.63

2.55

2.45

2.33

 

 

 

29

 

SHC

3.05

2.96

2.87

2.79

2.69

2.57

 

 

 

31

 

SHC

3.28

3.20

3.11

3.02

2.92

2.80

 

 

 

 

 

TC

4.08

3.91

3.73

# 3.55

3.34

3.07

 

 

 

 

 

CM

0.98

1.06

1.13

1.22

1.40

1.58

 

 

 

21

 

SHC

1.84

1.75

1.66

1.58

1.48

1.36

 

 

19

23

 

SHC

2.07

1.99

1.90

1.81

1.72

1.60

 

 

 

25

 

SHC

2.31

2.22

2.14

2.05

1.95

1.83

 

 

 

27

 

SHC

2.55

2.46

2.37

2.29

2.19

2.07

 

 

 

29

 

SHC

2.79

2.70

2.61

2.53

2.43

2.31

 

 

 

31

 

SHC

3.02

2.94

2.85

2.77

2.67

2.55

 

 

 

 

 

TC

4.33

4.14

3.95

3.76

3.54

3.25

 

 

 

 

 

CM

1.01

1.09

1.16

1.25

1.44

1.62

 

 

 

23

 

SHC

1.81

1.72

1.64

1.55

1.46

1.34

 

 

21

25

 

SHC

2.05

1.96

1.87

1.79

1.69

1.58

 

 

 

27

 

SHC

2.28

2.20

2.11

2.03

1.93

1.81

 

 

 

29

 

SHC

2.52

2.43

2.35

2.27

2.17

2.05

 

 

 

31

 

SHC

2.76

2.67

2.59

2.50

2.41

2.29

 

 

 

 

 

TC

4.59

4.39

4.19

3.95

3.70

3.44

 

 

 

 

 

CM

1.03

1.12

1.19

1.28

1.47

1.66

 

 

23

25

 

SHC

1.76

1.68

1.59

1.50

1.40

1.30

 

 

 

27

 

SHC

2.00

1.92

1.83

1.73

1.63

1.53

 

 

 

29

 

SHC

2.24

2.15

2.07

1.97

1.87

1.77

 

 

 

31

 

SHC

2.48

2.39

2.30

2.21

2.11

2.01

 

 

 

 

 

 

 

 

 

 

 

 

 

TC : Total Cooling Capacity (kW)

SHC : Sensible Heat Capacity (kW)

CM : Compressor Input (kW)

Rating conditions (#Mark) are

Outdoor Ambient Temp. 35 °C D.B.

Indoor Unit Entering Air Temp. 27 °C D.B. / 19 °C W.B.