6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit

SAP-K77RAX

 

 

 

 

 

 

Outdoor Unit

SAP-C77RAX

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

Fan Motor

Fan Motor

Compressor

 

Performance at

 

 

 

 

 

230V Single-phase 50Hz

 

Rating Conditions

 

Running amp.

A

 

0.17

0.22

3.21

3.60

 

 

 

Power input

kW

 

0.028

0.045

0.697

0.770

Full Load Conditions

Running amp.

A

 

0.17

0.22

3.71

4.10

 

 

 

Power input

kW

 

0.028

0.045

0.827

0.900

Rating conditions:

Indoor air temperature:

27

°C D.B. / 19 °C W.B.

 

 

 

 

 

Outdoor air temperature:

35

°C D.B.

 

 

 

Full Load conditions: Indoor air temperature:

32

°C D.B. / 23 °C W.B.

 

 

 

 

 

Outdoor air temperature:

43

°C D.B.

 

 

 

Indoor Unit

SAP-K97RAX

 

 

 

 

 

 

Outdoor Unit

SAP-C97RAX

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

Fan Motor

Fan Motor

Compressor

 

Performance at

 

 

 

 

 

230V Single-phase 50Hz

 

Rating Conditions

 

Running amp.

A

 

0.17

0.27

4.11

4.55

 

 

 

Power input

kW

 

0.028

0.057

0.887

0.972

Full Load Conditions

Running amp.

A

 

0.17

0.27

5.41

5.85

 

 

 

Power input

kW

 

0.028

0.057

1.177

1.262

Rating conditions:

Indoor air temperature:

27

°C D.B. / 19 °C W.B.

 

 

 

 

 

Outdoor air temperature:

35

°C D.B.

 

 

 

Full Load conditions: Indoor air temperature:

32

°C D.B. / 23 °C W.B.

 

 

 

 

 

Outdoor air temperature:

43

°C D.B.

 

 

 

Indoor Unit

SAP-K127RAX

 

 

 

 

 

 

Outdoor Unit SAP-C127RAX

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

Fan Motor

Fan Motor

Compressor

 

Performance at

 

 

 

 

 

230V Single-phase 50Hz

 

Rating Conditions

 

Running amp.

A

 

0.17

0.27

5.66

6.10

 

 

 

Power input

kW

 

0.028

0.062

1.215

1.305

Full Load Conditions

Running amp.

A

 

0.17

0.27

7.56

8.00

 

 

 

Power input

kW

 

0.028

0.062

1.660

1.750

Rating conditions:

Indoor air temperature:

27

°C D.B. / 19 °C W.B.

 

 

 

 

 

Outdoor air temperature:

35

°C D.B.

 

 

 

Full Load conditions: Indoor air temperature:

32

°C D.B. / 23 °C W.B.

 

 

 

 

 

Outdoor air temperature:

43

°C D.B.

 

 

 

29

Page 29
Image 29