7-2. Recommended Wire Length and Diameter

Regulations on wiring diameter differ from locality to locality. For field wiring requirements, please refer to your local electrical codes. Carefully observe these regulations when carrying out the installation.

Table 2 lists recommended wire lengths and diameters for power supply systems.

NOTE

Refer to the wiring system diagram (Fig. 6) for the meaning of (A) and (B) in Table 2.

Table 2

Cross-Sectional

(A) + (B)

(A) Power Supply Wiring Length (m)

 

Fuse or

Area (mm2)

(B) Power Line Length (m)

 

 

Circuit Breaker

 

 

 

 

Model

 

2

3.5

Capacity

C77 / 97

 

33

51

10A

C127

 

27

41

 

 

WARNING

Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).

Each wire must be firmly connected.

No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part.

WARNING

To avoid the risk of electrical shock, each air conditioner unit must be grounded.

CAUTION

Be sure to connect the power supply line to the outdoor unit as shown in the wiring diagram. The indoor unit draws its power from the outdoor unit.

WIRING SYSTEM DIAGRAM

INDOOR

(B)

OUTDOOR

UNIT

UNIT

Terminal

 

Terminal

1

 

1

2

 

2

3

Grounding line

3

 

 

 

(A)

 

 

L

L

 

Power supply

N

Single-phase 220-240VAC 50Hz N

Grounding line

Fig. 6

34

Page 34
Image 34