Sanyo Sanyo Split System Air Conditoner Troubleshooting, Operating Range, Possible Cause, Remedy

Models: Sanyo Split System Air Conditoner SAP-K77RAX

1 68
Download 68 pages 41.42 Kb
Page 67
Image 67
 TROUBLESHOOTING

Trouble TROUBLESHOOTING Possible Cause

If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or service center.

Trouble

 

Possible Cause

 

Remedy

 

 

 

 

Air conditioner does

1.

Power failure.

1. Restore power.

not run at all.

2.

Leakage circuit

2.

Contact service

 

 

 

breaker tripped.

 

center.

 

3.

Line voltage is too

3.

Consult your

 

 

low.

 

electrician or

 

 

 

 

dealer.

 

4.

Batteries in remote

4.

Replace batteries.

 

 

control unit have

 

 

 

 

run down.

 

 

 

 

 

OPERATION lamp

Trouble in system.

Contact service

blinks and air

 

 

center.

conditioner does not

 

 

 

 

operate.

 

 

 

 

 

 

 

Compressor runs but

Obstruction in front of

Remove obstruction.

soon stops.

condenser coil.

 

 

 

 

 

 

 

Poor cooling

1.

Dirty or clogged air

1.

Clean air filter to

performance.

 

filter.

 

improve airflow.

 

2.

Heat source or

2.

Eliminate heat

 

 

many people in

 

source if possible.

 

 

room.

 

 

 

3.

Doors and/or

3.

Shut them to keep

 

 

windows are open.

 

the heat out.

 

4.

Obstacle near air

4.

Remove it to

 

 

intake or air

 

ensure good

 

 

discharge port.

 

airflow.

 

5.

Thermostat is set

5.

Set the

 

 

too high for

 

temperature lower.

 

 

cooling.

 

 

 

 

 

Clicking sound is

In cooling operation,

This is normal, and

heard from the air

any plastic parts may

the sound will soon

conditioner.

shrink due to a

disappear.

 

sudden temperature

 

 

 

change. In this event,

 

 

 

a clicking sound may

 

 

 

occur.

 

 

 

 

 

 

OPERATION lamp

The use of cellular

1.

Turn off the power

lights but outdoor unit

phones near the air

 

then restart the air

will not run.

conditioner may

 

conditioner after a

 

cause disturbance to

 

while.

 

its normal operation.

2.

Consult your

 

 

 

 

 

 

 

dealer.

 

 

 

 

 

Remedy OPERATING RANGE  OPERATING RANGE

The air conditioner is operable within the temperature ranges as listed below:

 

Temperature

Indoor air

Outdoor air

 

 

temperature

temperature

 

 

 

 

 

COOLING

Max.

32

°C DB /

43 °C DB

 

 

23

°C WB

 

 

 

 

 

 

 

Min.

19

°C DB /

19 °C DB

 

 

14

°C WB

 

 

 

 

 

 

OI-018-15-EG

15

 

Page 67