MENU SETTINGS (MENU WINDOW)

(User Level: ID4)

 

 

MONITOR SET tab

This sets the window settings for the monitor that is connected to a DVR. Select the DVR to be set from the “TARGET” window. The selected DVR will change to blue.

1

2

3

4

<MONITOR SET>

1SEQUENCE (Default setting: 1)

Use the spin buttons to select the display time (window switching interval) for each channel in the sequence screen, and then click [APPLY].

Available settings: 1–30 seconds

<ALARM MONITOR SET>

2DISPLAY (Default setting: QUAD) Select the display window to use when an alarm occurs, and then click [APPLY].

Available settings:

FULL: Only the channel where the alarm occurs is displayed in a full window.

QUAD: A 4-screen quad screen is displayed including the channel where the alarm occurred.

3ALARM PRIORITY (Default setting: LAST) This sets the screen display order if multiple alarms occur at more than one channel. Use the buttons to select the display order and then click [APPLY]. This setting is only enabled if the previous “DISPLAY” setting has been set to “FULL”.

Available settings:

LAST: Images from the last alarm occurring have priority.

FIRST: Images from the first alarm occurring have priority.

SWITCH: Images switch between multiple alarms at intervals of 1 second.

38

English

Page 39
Image 39
Sanyo VA-SW80LITE instruction manual Monitor SET tab, Available settings 1-30 seconds, Alarm Monitor SET