Connecting Devices
Adjusting Flange Back
Flange back adjustment may be required to correct a focal distance error generated due to attachment thickness of the installed lens.
Normally you do not have to make any adjustment, however, you can adjust focus of the installed lens with auto iris, when it provides images out of focus at the maximum telephoto position. To adjust the flange back, follow the steps below.
1Loosen the lock screw. (M2: +)
2Set the zoom lens to the |
maximum telephoto position |
and then adjust focus by |
3Set the zoom lens to the | Note: The flange back lock screw is tightened | |
|
| |
| maximum | completely when its tip hits the invisible |
| bottom, even though the screw head | |
| and then adjust focus by using | |
| may seem still up in the air. Do not screw | |
| the flange back adjusting lever. | down any further beyond this normal |
|
| position as illustrated in Fig. 1. |
|
|
turning the focus ring of the |
lens. |
2
4Repeat steps 2 and 3 until the image stays
Flange back lock screw
Fig. 1
Connection
1
3
4