Specifying Alarm Output

ALARM SIGN (Alarm display)

1Select “ALARM SIGN” on the “ALARM SETTING”

2Set “MENU” to “END” and press the SET button.

 

screen and specify a displaying time.

 

RFinishes the settings screen and returns to the normal

 

 

 

monitoring screen.

ALARM SETTING

ALARM IN

SET

ALARM

OUT

OFF

ALARM

SIGN

OFF

If you want to return to the previous screen, select “BACK” and press the SET button.

PRESET

OFF

MENU

BACK

Select from: OFF (not display), 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M (S = second, M = minute)

RIf you specify any value other than “OFF”, the camera name on the screen will blink for the specified time of duration when an alarm occurs.

Alarm occurred

CAM1

MEMO: • If the camera name is not given, “??...” will blink on the screen.

Even if the “TITLE” is specified as “OFF”, the camera name will blink when an alarm occurs.

(See page 16)