Specifying Alarm Output

For accessing the MAIN MENU, see page 13 – 14.

If you have connected an external beeper or indicator to the alarm output terminal (ALARM OUT) on the rear panel, specify the following settings. You can also obtain a notification on the screen while an alarm occurs. (For connecting alarm devices, see page 10.)

 

MAIN MENU

 

 

 

 

ALARM SETTING

 

LANGUAGE

SET

 

 

 

ALARM IN

 

 

TITLE

OFF

 

 

 

ALARM OUT

ON

 

SYNC

INT

 

 

 

ALARM SIGN

OFF

 

EXPOSURE

SET

 

 

 

 

 

 

DAY/NIGHT

AUTO

 

 

 

 

 

 

WHITE BALANCE

 

SET

 

 

 

SET

 

ALARM

SET

 

 

 

 

 

 

 

 

 

ALARM

OPTION

SET

 

ALARM

 

PRESET

OFF

PRESET

OFF

 

ON

(SET)

MENU

END

 

OUT

MENU

BACK

 

 

 

 

 

 

ALARM OUT SETTING (Alarm output)

1Select “POLARITY” and specify a polarity for the

2Select “ALARM TIME” and specify duration time

 

signal.

 

to output alarm.

ALARM OUT SETTING

POLARITY

NO

ALARM TIME

5S

NO: Normal Open (Closes when alarm input is detected).

NC : Normal Close (Opens when alarm input is detected).

MEMO: For the electrical characteristics of alarm output, the nominal output of the open collector (grounded emitter) is 18 V 25 mA.

Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M (S = second, M = minute)

MEMO: You can display alarm on the monitor screen. (See page 45)

3Set “MENU” to “END” and press the SET button.

RFinishes the settings screen and returns to the normal monitoring screen.

If you want to return to the previous screen, select “BACK” and press the SET button.

Settings/

Adjustments

English 44