Specifying Alarm Output | For accessing the MAIN MENU, see page 13 – 14. |
If you have connected an external beeper or indicator to the alarm output terminal (ALARM OUT) on the rear panel, specify the following settings. You can also obtain a notification on the screen while an alarm occurs. (For connecting alarm devices, see page 10.)
| MAIN MENU |
|
|
|
| ALARM SETTING | |
| LANGUAGE | SET |
|
|
| ALARM IN |
|
| TITLE | OFF |
|
|
| ALARM OUT | ON |
| SYNC | INT |
|
|
| ALARM SIGN | OFF |
| EXPOSURE | SET |
|
|
|
|
|
| DAY/NIGHT | AUTO |
|
|
|
|
|
| WHITE BALANCE |
| SET |
|
|
| SET |
| ALARM | SET |
|
|
| ||
|
|
|
|
|
| ||
ALARM | OPTION | SET |
| ALARM |
| PRESET | OFF |
PRESET | OFF |
| ON | ||||
(SET) | MENU | END |
| OUT | MENU | BACK | |
|
|
|
|
|
|
ALARM OUT SETTING (Alarm output)
1Select “POLARITY” and specify a polarity for the | 2Select “ALARM TIME” and specify duration time | ||
| signal. |
| to output alarm. |
ALARM OUT SETTING
POLARITY | NO |
ALARM TIME | 5S |
NO: Normal Open (Closes when alarm input is detected).
NC : Normal Close (Opens when alarm input is detected).
MEMO: For the electrical characteristics of alarm output, the nominal output of the open collector (grounded emitter) is 18 V 25 mA.
•Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M (S = second, M = minute)
MEMO: You can display alarm on the monitor screen. (See page 45)
3Set “MENU” to “END” and press the SET button.
RFinishes the settings screen and returns to the normal monitoring screen.
•If you want to return to the previous screen, select “BACK” and press the SET button.
Settings/ | Adjustments |
English 44