Specifying Alarm Input
ISelect “DURATION” and specify a time until the next alarm input becomes enabled.
MOTION SETTING
MASKING | OFF |
SENSITIVITY | SET |
DURATION | 5S |
PRESET | OFF |
MENU | BACK |
•Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M (S = second, M = minute)
Note: A new detection or an alarm output cannot be performed until the specified time of duration elapses.
JSet “MENU” to “BACK” and press the SET button.RReturns to the “ALARM IN SETTING” screen.
| ALARM IN SETTING | |
| MODE | ALM |
| POLARITY | NO |
| MOTION | OFF |
| MOTION SET | SET |
| ZOOM | OFF |
| ZOOM TIME | 5S |
| DURATION | 5S |
NO | : Normal Open (When closed, alarm input is detected.) | |
NC | : Normal Close (When opened, alarm input is detected.) |
LSelect “MOTION” and specify the detection logic of the motion sensor and the alarm input.
OFF : The motion sensor is unused: Detects when an external sensor responded.
AND : Detects when both the motion sensor and an external sensor responded. (You cannot select this option when the “MODE” is specified with “COLOR”.)
OR : Detects when either the motion sensor or an external sensor responded. (During the “COLOR” mode, detection is solely dependent on the responsiveness of the motion sensor.)
Note: While the “SENSE UP” capability is enabled, the motion sensor does not work. If “SENSE UP” has been set to other than “OFF”, this setting is not available. (See page 28)