Appendix A—Register List

Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Electronic Trip Units

48049-136-05

Appendix A—Register List

Rev. 01, 07/2012

 

 

Appendix A—Register List

ENGLISH

List of Registers

The quantities are listed in alphabetical order according to the SMS topic name.

NOTE: A system scan rate of 500 ms or greater is recommended to minimize communications timeout issues.

This is an abbreviated list of registers. For a complete list of registers, contact your local sales office.

To access available registers, the following address scheme applies.

Module

Module Name

Equation

Address Range

 

 

 

 

BCM

Circuit Breaker Communication Module

--

1–47

 

 

 

 

CCM

Cradle Communication Module

BCM + 50

51–97

 

 

 

 

PM

Protection Module (Internal to trip unit)

BCM + 100

101–147

 

 

 

 

MM

Meter Module (Internal to trip unit)

BCM + 200

201–247

 

 

 

 

Table 10:

Register List

 

 

 

 

 

 

 

 

 

 

 

 

 

SMS Topic Name

User Description

Number of

Register*

Module*

Units

Scale/Bitmask

Registers*

 

 

 

 

 

 

 

810DBrkrStatus

 

Circuit Breaker Status

1

661

BCM

 

Bit 0; ON = closed, OFF = open

810DBrkrTripStat

Circuit Breaker Trip Unit Status

1

661

BCM

 

Bit 2; ON = tripped, OFF = not tripped

 

 

 

 

 

 

 

 

BCM_SN

 

BCM Serial Number

4

516

BCM

 

ASCII text

 

 

 

 

 

 

 

Bit 8 = disconnected

BkrPos

 

Circuit Breaker Position

1

661

CCM

 

Bit 9 = connected

 

 

 

 

 

 

 

Bit 10 = test position

 

 

 

 

 

 

 

 

DT_3Regs

 

Device Clock Date/Time

3

679

BCM

 

3-register date/time format

EnableCloseBkr

 

Remote Closing Enabled

1

669

BCM

 

Bit 2; ON = enabled, OFF = not enabled

 

 

 

 

 

 

 

 

EnableOpenBkr

 

Remote Opening Enabled

1

669

BCM

 

Bit 1; ON = enabled, OFF = not enabled

EnableRemCtrl

 

Remote Control Enabled

1

669

BCM

 

Bit 3; ON = auto (enabled),

 

 

OFF = manual (not enabled)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IA

 

Current A

1

8821

PM

A

Unity

IA_PCT

 

Current A % Load

1

8837

PM

%

Unity

 

 

 

 

 

 

 

 

IB

 

Current B

1

8822

PM

A

Unity

IB_PCT

 

Current B % Load

1

8838

PM

%

Unity

 

 

 

 

 

 

 

 

IC

 

Current C

1

8823

PM

A

Unity

IC_PCT

 

Current C % Load

1

8839

PM

%

Unity

 

 

 

 

 

 

 

 

IG

 

Current G

1

8825

PM

A

Unity

IG_PCT

 

Current G % Load

1

8841

PM

%

Unity

 

 

 

 

 

 

 

 

IG_PCT_VIGI

 

Current G (VIGI) % Load

1

8842

PM

%

Hundredths

IG_VIGI

 

Current G (VIGI)

1

8826

PM

A

Thousandths

 

 

 

 

 

 

 

 

IMax

 

Current Max Present

1

8820

PM

A

Unity

IN

 

Current N

1

8824

PM

A

Unity

 

 

 

 

 

 

 

 

IN_PCT

 

Current N % Load

1

8840

PM

%

Unity

LDPUValue

 

Long Delay Pickup Value

2

8756

PM

A

Modulo 10,000 format**

MaxIA

 

Max Current A

1

8827

PM

A

Unity

MaxIB

 

Max Current B

1

8828

PM

A

Unity

 

 

 

 

 

 

 

 

MaxIC

 

Max Current C

1

8829

PM

A

Unity

MaxIG

 

Max Current G

1

8831

PM

A

Unity

 

 

 

 

 

 

 

 

MaxIG_VIGI

 

Max Current G (VIGI)

1

8832

PM

A

Thousandths

MaxIN

 

Max Current N

1

8830

PM

A

Unity

 

 

 

 

 

 

 

 

NominalCurrent

 

Circuit Breaker Nominal Current

1

8750

PM

A

Unity

ReadyToClose

 

Circuit Breaker Ready to Close

1

661

BCM

 

Bit 5; ON = yes, OFF = no

 

 

 

 

 

 

 

 

Continued on next page

36-EN

© 1999–2012 Schneider Electric All Rights Reserved