Table 26: Extended Message Codes

Code

Extended message

 

 

 

 

00h

MODIFY DATA POINTERS

 

 

01h

SYNCHRONOUS DATA TRANSFER REQUEST

 

 

02h

Reserved

 

 

03h

WIDE DATA TRANSFER REQUEST

 

 

04h

PARALLEL PROTOCOL REQUEST

 

 

05h

MODIFY BIDIRECTIONAL DATA POINTER

 

 

06h - FFh

Reserved

 

 

1.The EXTENDED MESSAGE ARGUMENTS are specified within the Extended Message Descriptions in Paragraphs referenced in Table 27.

4.3Message categories

The messages supported by the various drives are divided up into categories and listed in tables in the follow- ing subsections. The individual drive’s Product Manual. Table 27 lists messages that are supported by the par- ticular drive. In the tables, the message code values are given a direction specification (In-Out). Detailed descriptions follow the tables. Messages other than those supported by a drive are answered by the drive with a MESSAGE REJECT message.

4.3.1LINK CONTROL MESSAGES Table 27: Link Control message codes

 

Support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IU transfers

IU transfers

 

 

 

 

Clear

 

disabled

enabled

 

 

 

Direction

 

 

 

 

 

 

 

 

Reference

 

 

attention

 

 

 

 

 

 

 

 

 

 

Code

Init

 

Targ

Init

 

Targ

Message name

section

In

Out

condition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04h

O

 

O

O

 

O

DISCONNECT

4.3.2

In

Out

Yes

 

 

 

 

 

 

 

 

 

 

 

 

80h+

M

 

O

NS

 

NS

IDENTIFY

4.3.3

In

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

80h+

M

 

M

NS

 

NS

IDENTIFY

4.3.3

 

Out

Not

 

 

 

 

required

 

 

 

 

 

 

 

 

 

 

 

23h

O

 

O

NS

 

NS

IGNORE WIDE RESIDUE

4.3.4

In

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

05h

M

 

M

M

 

M

INITIATOR DETECTED

4.3.5

 

Out

Yes

 

 

ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0Ah

O

 

O

NS

 

NS

LINKED COMMAND

 

In

 

N/A

 

 

COMPLETE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09h

M

 

M

M

 

M

MESSAGE PARITY

4.3.7

 

Out

Yes

 

 

ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07h

M

 

M

M

 

M

MESSAGE REJECT

4.3.8

In

Out

Yes

 

 

 

 

 

 

 

 

 

 

 

 

01h,05h,00h

O

 

O

O

 

O

MODIFY DATA POINTER

4.3.9

In

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

01h,09h,05h

O

 

O

O

 

O

MODIFY BIDIREC-

4.3.9

In

 

N/A

 

 

TIONAL DATA POINTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08h

M

 

M

M

 

M

NO OPERATION

4.3.11

 

Out

Yes

 

 

 

 

 

 

 

 

 

 

 

 

01h,06h,04h

M

 

M

M

 

M

PARALLEL PROTOCOL

4.3.12

In

Out

Yes

 

 

REQUEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parallel SCSI Interface Product Manual, Rev. A

85

Page 99
Image 99
Seagate Ultra 160, Ultra 320 Message categories, Extended Message Codes, Link Control Messages Link Control message codes