Table 50:

SPI L_Q information unit type

 

 

 

Codes

Type

Description

 

 

 

 

 

 

 

 

 

 

 

Sent by a SCSI initiator port device to indicate a SPI command information unit shall follow

 

 

 

this SPI L_Q information unit. Indicates the initiator device shall not send any more SPI com-

01h

 

Last

mand information units during the current connection. The value of the Data Length field shall

 

Command

be greater than or equal to 14h and less than or equal to 90h. The iuCRC Interval field shall be

 

 

 

 

 

set to zero and ignored by the target device. The Bidi Direction field shall be set to zero and

 

 

 

ignored by the receiving SCSI target device.

 

 

 

 

 

 

 

Sent by a SCSI initiator port device to indicate a SPI command information unit shall follow

 

 

 

this SPI L_Q information unit. Indicates the initiator device has another SPI L_Q information

02h

 

Multiple

unit and SPI command information unit during the current connection. The value of the Data

 

Length field shall be greater than or equal to 14h and less than or equal to 90h. The iuCRC

 

Command

 

 

Interval field shall be set to zero and ignored by the SCSI target device. The IUCRC Interval

 

 

 

 

 

 

field shall be set to zero and ignored by the SCSI target device. The BIDI Direction field shall

 

 

 

be set to zero and ignored by the receiving target device.

 

 

 

 

 

 

 

Sent by a SCSI target port device to indicate a SPI data information unit shall follow this SPI

04h

 

Data

L_Q information unit. The Data Length field shall not be set to zero. For a bidirectional com-

 

mand, the direction of the SPI data information unit shall be indicated in the BIDI Direction

 

 

 

 

 

 

field of the SPI L_Q information unit as defined in Table 51.

 

 

 

 

 

 

 

Sent by a SCSI target port device to indicate an unspecified number of SPI data stream infor-

05h

 

Data

mation units shall follow this SPI L_Q information unit. The Data Length field shall not be set to

 

stream

zero. For a bidirectional command, the direction of the SPI data stream information units shall

 

 

 

 

 

be indicated in the BIDI Direction field of the SPI L_Q information unit as defined in Table 51.

 

 

 

 

 

 

 

Sent by a SCSI target port device to indicate a SPI status information unit may follow this SPI

08h

 

 

L_Q information unit. A length of zero in the Data Length field shall indicate no SPI status

 

Status

information unit shall follow the SPI L_Q information unit (see Section 6.2.5). The iuCRC Inter-

 

 

 

val field shall be set to zero and ignored by the SCSI target device. The BIDI Direction field

 

 

 

shall be set to zero and ignored by the receiving SCSI initiator device.

 

 

 

 

F0H -

 

 

vendor-specific.

FFh

 

 

 

 

 

 

 

 

 

All

 

 

Reserved.

others

 

 

 

 

 

 

 

 

 

[2]Tag field is a 16-bit unsigned integer assigned by the application client and sent to the initiator in the Send SCSI Command request. See Section 4.4.1, Task attribute message overview and codes.

[3]The Logical Unit Number field specifies the address of the logical unit of the I_T_L_Q nexus for the cur- rent task. The structure of the Logical Unit Number field shall be as defined in the SCSI Architecture Model-4 standard, Section 4.11. If the addressed logical unit does not exist, the task manager shall follow the SCSI rules for selection of invalid logical units as defined in the SCSI Primary Commands - 4 (SPC-4) standard. The eight bytes in this field provide 4 levels of addressing. Bytes 4-5 address the first level, etc. to bytes 10-11, which address the fourth level. If LUN in SPI LQ information unit packet is X which is greater than 0x3F (>63), then the LUN in ID message sent back will be set to 0x3F (63). If LUN in SPI LQ information unit packet is X which is not greater than 0x3F (>63), then the LUN in ID message sent back will be set to X.

[4]The Data Length field contains the length in bytes of the following information units. For SPI data stream information units, the data length field contains the length in bytes of each SPI data stream information unit that follows (i.e., the total number of bytes transferred would equal the data length times the number of SPI data stream information units transferred). The data length shall not include any of the 4-byte iuCRC nor any transmitted pad bytes (e.g., a data length of 509 with a iuCRC interval of zero or greater