Sharp AY-XPC9JR Additional Notes On Operation, GB-13, Maintenance After Air Conditioner Season

Models: AY-XPC12JR AY-XPC7JR AY-XPC9JR

1 116
Download 116 pages 50.96 Kb
Page 15
Image 15
MAINTENANCE AFTER AIR

MAINTENANCE AFTER AIR

CONDITIONER SEASON

1 Operate the unit in the SELF CLEAN operation to allow the mechanism to thoroughly dry.

2 Stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air conditioner.

3 Clean the filters, then reinstall them.

MAINTENANCE BEFORE AIR CONDITIONER SEASON

1 Makedirty. sure that the air filters are not

2 Make sure that nothing obstructs the air inlet or outlet.

CHANGING THE AIR PURIFYING FILTER

The filters should be changed every 3 ~ 6 months

1 Remove the air filters.
2 Change the air purifying filters.

1Take off the old air purifying filters from the air filters.

2Set the new air purifying filters, under the filter stoppers located on the air filters.

Filter stopper

3 Reinstall the air filters.

NOTE:

The dirty air purifying filters are not washable for reuse. The new filters are available at your nearest dealer.

Replacement filter: Type AZ-F920F

Disposal of Filters

Please dispose of replaced filters according to the local disposal laws and regulations.

AIR PURIFYING filter materials Filter:Polypropylene Frame:Polyester

ADDITIONAL NOTES ON

OPERATION

OPERATING TEMPERATURE RANGE

 

 

INDOOR TEMP.

OUTDOOR TEMP.

ENGLISH

 

 

 

 

upper limit

32˚C

46˚C (Single use)

 

 

43˚C (Multi use)

 

COOLING

 

 

 

lower limit

21˚C

–10˚C (Single use)

 

 

 

 

21˚C (Multi use)

 

 

 

 

 

HEATING

upper limit

27˚C

24˚C

 

lower limit

–15˚C

 

The built-in protective device may prevent the unit from operating when used out of this range.

Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.

WHEN POWER FAILURE OCCURS

This air conditioner has a memory function to store settings when a power failure occurs.

After power recovery, the unit will automatically re- start in the same settings which were active before the power failure, except for timer settings.

If the timers were set before a power failure, they will need to be re-set after power recovery.

PREHEATING FUNCTION

In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.

DE-ICING FUNCTION

When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.

After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

HEATING EFFICIENCY

The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.

If the heating efficiency is reduced due to low outside temperatures, use an additional heater.

It takes time to warm up and heat the entire room because of the forced air circulation system.

GB-13

Page 15
Image 15
Sharp AY-XPC9JR Additional Notes On Operation, GB-13, Maintenance After Air Conditioner Season, Remove the air filters