MAINTENANCE AFTER AIR
CONDITIONER SEASON
1 Operate the unit in the SELF CLEAN operation to allow the mechanism to thoroughly dry.
2 Stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air conditioner.
3 Clean the filters, then reinstall them.
MAINTENANCE BEFORE AIR CONDITIONER SEASON
1 Makedirty. sure that the air filters are not
2 Make sure that nothing obstructs the air inlet or outlet.
CHANGING THE AIR PURIFYING FILTER
The filters should be changed every 3 ~ 6 months
1 Remove the air filters.
2 Change the air purifying filters.
1Take off the old air purifying filters from the air filters.
2Set the new air purifying filters, under the filter stoppers located on the air filters.
Filter stopper
3 Reinstall the air filters.
NOTE:
•The dirty air purifying filters are not washable for reuse. The new filters are available at your nearest dealer.
Replacement filter: Type
Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations.
AIR PURIFYING filter materials Filter:Polypropylene Frame:Polyester
ADDITIONAL NOTES ON
OPERATION
OPERATING TEMPERATURE RANGE
|
| INDOOR TEMP. | OUTDOOR TEMP. | ENGLISH |
|
|
| ||
| upper limit | 32˚C | 46˚C (Single use) |
|
| 43˚C (Multi use) |
| ||
COOLING |
|
|
| |
lower limit | 21˚C |
| ||
|
| |||
| 21˚C (Multi use) |
| ||
|
|
|
| |
HEATING | upper limit | 27˚C | 24˚C |
|
lower limit | – |
|
•The
•Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re- start in the same settings which were active before the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
•When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic
•After
HEATING EFFICIENCY
•The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.
•If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
•It takes time to warm up and heat the entire room because of the forced air circulation system.