PC Operation (Continued)

RS-232C command table

<How to read the command table>

Command :

38

Command field

 

Direction :

W

When the “Parameter” is set in the parameter field ( 38 ), the

 

 

command functions as described under “Control/Response Contents”.

 

R

The returned value indicated under “Reply” can be obtained by setting

 

 

“????”, “___?” or “???+” (repeater control) in the parameter field ( 38 ).

Parameter :

38

Parameter

 

Reply :

Response

Returned value

A circle indicates commands which can be used in power standby mode.

Power control, etc.

 

CONTROL ITEM

 

Command

 

Direction

 

Parameter

 

Reply

 

CONTROL/RESPONSE CONTENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SETTING

 

 

POWR

 

W

 

0

 

 

 

Switches to standby.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Returns from standby.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

0

 

Standby state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Normal status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Power standby state ("Mode2" in "Power Management").

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHANNEL DISPLAY

 

 

DISP

 

W

 

 

 

 

It displays channel display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLUME

 

 

VOLM

 

WR

 

0 - 60

 

0 - 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUTE

 

 

MUTE

 

WR

 

0

 

0

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYNC CHECK

 

 

SYNC

 

W

 

0

 

 

 

It returns Yes/No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

It returns frequency.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUSE OF LAST STANDBY

 

 

STCA

 

W

 

0

 

 

 

Content initialization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

0

 

No standby operation (except remote control and monitor button operation) after

 

 

 

 

 

 

 

 

 

 

 

 

 

initialization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Electrical standby due to some error condition (See cause of last error)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Invalid input has continued for a long time during PC display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

It entered standby mode (PC mode: "Mode1" in "Power Management")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

It entered standby mode (PC mode: "Mode2" in "Power Management")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

It entered standby mode by the command from RS-232C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUSE OF LAST ERROR

 

 

ERCA

 

WR

 

0

 

 

 

Content initialization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

No detectable error has occurred

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Invalid input has continued for a long time during PC display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Internal bus error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Abnormal temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

Board connection error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Lamp error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Electrical system error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Error in communication with microcomputer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER CONTROL

BRIGHTNESS

 

VLMP

 

WR

 

±8

 

±8

 

Brightness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

PMNG

 

WR

 

0

 

0

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

Mode1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

2

 

Mode2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LANGUAGE

 

 

LANG

 

WR

 

1

 

 

 

German

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

French

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

Spanish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

Japanese

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

English

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

 

RSET

 

W

 

4 digits

 

 

 

Input 4-digit PIN for parameter. It resets to factory preset value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RSE+

 

W

 

4 digits

 

 

 

Input 4-digit PIN for parameter. It resets to factory preset value. For Repeater

 

 

 

 

 

 

 

 

 

 

 

 

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 