[Display Area] tab

FTP Server/Client Scheduler

Client Scheduler

[Display Area] tab

“Display area for distributed program”

When the display area of the program and the resolution of the panel are different, this tab allows you to display the program regardless of the display area set for the program.

Check the “Always display the distributed program in the following area” check box and set the area in which the program is to be displayed.

[Power Control] tab

Manages power on target PCs currently being confgured.

“Shutdown on the designated time” check box

Check this box to turn off the target PC at the specifed time.

“Reboot on the designated time” check box

Check this box to restart the target PC at the specifed time.

[FTP Server] tab Sets the FTP Server.

“User name”: Must be kept within 30 alphanumeric characters.

“Password”: Must be kept within 30 alphanumeric characters.

“Port Number”: Enter a value between 1 and 32000.

If you have installed the Viewer Version, a unique FTP Server will be installed, and started as a service. The default TCP/IP port numbers are 20 and 21. If this port number is already used by another service, change the port number. The FTP settings of the panels registered with “Panel Management” on the control PC must use the same port number. (Fp.80)

[Panel Control] tab

“No panel” option button

Panels will not be controlled.

“Single panel” option button

Click [Connection Setting] and select the panel control method (RS-232C/LAN).

[Connection Setting]

Select either “RS-232C” or “LAN” from the [Connecting interface] option buttons.

 

Setting

Description

Default

RS-232C

COM port

COM1~COM256

COM1

Baud Rate

9600, 19200, 38400

9600

 

 

Host name or IP

Enter the host name or the IP address of the panel to be

-

 

address

controlled within 32 alphanumeric characters.

 

 

 

Data port

Enter a data port number between 1025 and 65535 for the

10008

 

panels to be controlled.

LAN

 

 

User name

Enter the username, if one exists for the panels to be

-

 

 

controlled, in 8 characters or less.

 

 

 

 

Password

Enter the password, if one exists for the panels to be

-

 

controlled, in 8 characters or less.

 

 

 