Wired Remote Control Terminal Specifications

Specifications of wired remote control input

ø3.5 mm minijack

External: 5 V (1 A)

Internal: GND

Function and transmission codes

CONTROL

SYSTEM CODE

 

DATA CODE

 

 

EXTERNAL

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10 C11 C12 C13 C14 C15

 

ON

1

0

1

1

0

0

1

1

0

1

0

1

0

1

0

OFF

1

0

1

1

0

0

1

1

0

1

0

0

1

1

0

VOLUME 

1

0

1

1

0

0

0

1

0

1

0

0

0

1

0

VOLUME 

1

0

1

1

0

1

0

1

0

1

0

0

0

1

0

MUTE

1

0

1

1

0

1

1

1

0

1

0

0

0

1

0

MENU

1

0

1

1

0

0

0

1

0

0

0

1

1

1

0

LENS

1

0

1

1

0

1

1

0

1

0

0

0

1

1

0

BLACK SCREEN

1

0

1

1

0

1

0

0

1

0

1

1

0

1

0

ENTER

1

0

1

1

0

1

1

1

0

1

0

1

0

1

0

RESIZE

1

0

1

1

0

0

1

1

1

1

0

1

0

1

0

UNDO

1

0

1

1

0

1

0

0

1

1

0

1

0

1

0

CONTROL

SYSTEM CODE

 

DATA CODE

 

 

EXTERNAL

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

C1

C2

C3

C4

C5

C6

C7

C8

C9

C10 C11 C12 C13 C14 C15

 

Freeze

1

0

1

1

0

1

0

1

1

0

0

0

1

1

0

Enlarge

1

0

1

1

0

1

0

1

1

0

1

1

0

1

0

AUTO SYNC

1

0

1

1

0

0

1

0

1

1

1

1

1

1

0

1

0

1

1

0

0

0

1

1

1

0

0

1

1

0

ƒ

1

0

1

1

0

1

0

1

1

1

0

0

1

1

0

ß

1

0

1

1

0

0

0

0

0

1

0

1

0

1

0

©

1

0

1

1

0

1

1

1

1

0

0

1

0

1

0

GAMMA

1

0

1

1

0

0

0

0

0

0

0

1

0

1

0

INPUT 1. 2. 3

1

0

1

1

0

0

0

1

1

0

1

1

1

1

0

INPUT 4. 5

1

0

1

1

0

0

1

1

0

1

1

0

1

1

1

To operate the mouse, left-click and right-click functions through the wired remote control input, connect the cable from the WIRED REMOTE control input terminal on the projector to the remote control. The codes for these functions are complex and are, therefore, not listed here.

Wired remote control function code

LSB

 

 

 

 

 

MSB

C1

System Code

C5

C6

Data Code

C13

C14

C15

1 0

1 1

0

*

* * * * *

* *

1

0

System codes C1 to C5 are fixed at “10110”.

Codes C14 and C15 are reverse confirmation bits, with “10” indicating “Front” and “01” indicating “Rear”.

Sharp remote control signal format

Transmission format: 15-bit format

D

D

D

D

D

D

D

D

D

D

D

D

D

67.5 ms

 

 

 

 

67.5 ms

 

 

 

 

 

 

 

Wave form of output signal: Output using Pulse Position Modulation

t

T1 T0

“1” “0” “0” “0”

t  264 µs

T0  1.05 ms

T1  2.10 ms

26.4 s

“0”

“1”

“0”

t

D

Pulse carrier frequency  455/12 kHz

Duty ratio  1:1

Transmission control code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 bit

 

 

 

 

 

Example of Reverse D to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1 C2 C3 C4 C5

C6 C7 C8 C9 C10 C11 C12 C13

C14 C15

D

C1

C2

C3

C4

C5

C6

 

C7

 

C8

 

C9

 

C10

 

C11

 

C12

 

C13

 

C14

 

C15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

1

1

0

1

 

0

 

0

 

0

 

0

 

0

 

0

 

0

 

1

 

0

System Address

Function Key Data Bit

Data

Mask

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Expansion

Deter-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mination

D

C1

C2

C3

C4

C5

C6

 

C7

 

C8

 

C9

 

C10

 

C11

 

C12

 

C13

 

C14

 

C15

 

 

 

 

 

 

1

0

1

1

0

0

1

1

 

1

1

1

1

1

0

1

D to D Common Data Bit

 

Reverse in D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

E-76

Page 77
Image 77
Sharp XG-P20XU operation manual Internal GND, Transmission control code