Replacing the Air Filter

This projector is equipped with two air filters to ensure the optimal operating condition of the projector.

The air filters should be cleaned every 100 hours of use. Clean the filters more often when the projector is used in a dusty or smoky location.

Have your nearest Authorized Sharp Industrial LCD Products Dealer or Service Center exchange the filter (PFILD0080CEZZ) when it is no longer possible to clean it.

Bottom View

Side and Rear View

Air filter

Air filter (not removable)

Cleaning and replacing the bottom air filter

Turn off the power and

Remove the bottom

3

Remove the air filter.

1 disconnect the power

2 filter cover.

 

cord.

 

 

 

Press POWER OFF. Wait until

Turn over the projector. Press the

Grasp the air filter between your

the cooling fan stops.

tab and lift open the filter cover

fingers and lift it out of the filter

Push the antenna completely

in the direction of the arrow.

cover.

down to its resting position.

 

 

 

 

Tab

 

 

4 Clean the air filter.

5 Replace the air filter.

6 cover.Replace the filter

Clean the dust off the air filter

Place the air filter underneath

Insert the tab on the end of the

and cover with a vacuum

the tabs on the filter frame.

filter cover into the filter cover

cleaner extension hose.

 

opening and press the filter

 

 

cover into position.

 

 

Tab

Be sure the filter cover is securely installed. The power will not turn on unless it is correctly installed.

Troubleshooting

Maintenance&

 

 

Cleaning the side air filter (not removable)

If dust or dirt has collected inside the air filter, clean the filter with a vacuum cleaner extension hose.

The side air filter cannot be removed.

E-70

Page 71
Image 71
Sharp XG-P20XU operation manual Replacing the Air Filter, Cleaning and replacing the bottom air filter