Shindaiwa DG1000MI Gauges, Battery Charge Monitoring Lamp charge lamp, Water Temperature Gauge

Models: DG1000MI

1 52
Download 52 pages 13.75 Kb
Page 12
Image 12
5.1.3 Battery Charge Monitoring Lamp (charge lamp)

5.1.3 Battery Charge Monitoring Lamp (charge lamp)

CHARGE

When the battery is not able to be charged during operation, the battery charge-monitoring lamp will flash.

In the event this occurs, stop the engine consult with the authorized distributor or our engineering section.

<Caution>

￿Battery Charge Monitor cannot detect the degradation of battery life nor the battery fluid level (refer to 8-6 Checking Battery)

5.2Gauges

5.2.1 Hour Meter (built into the Tachometer)

Hour Meter keeps track of utilization time. Use this meter to schedule your

 

 

HOUR METER

 

 

Preventative Maintenance. Note that the Hour Meter will operate, as long as

 

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

H

 

the start switch is in RUN position, regardless of whether the engine is operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or stopped.

5.2.2

Water Temperature Gauge

 

 

 

 

 

 

 

 

Water Temperature Gauge displays the temperature of engine coolant. Normal

temperature may vary depending on the environment, but it should be between 75 to 90 degree Celsius.

<Caution>

￿If the temperature exceeds normal value, disconnect the load, idle the engine at 1000min-1, and wait until the reading falls to the normal temperature range.

5.2.3Oil Pressure Gauge

Oil Pressure Gauge displays the pressure of engine oil. Normal pressure may

vary depending on the environment, but it should display 0.98 – 4.9 x 100kPa (1-5kgf/cm2). However, under cold weather, the pressure gauge may displays

higher reading. Continue idling until the pressure falls to normal range.