Shindaiwa DG1000MI manual ① ② ③, Cleaning / Changing Air Filter Element

Models: DG1000MI

1 52
Download 52 pages 13.75 Kb
Page 41
Image 41
10.3 Cleaning / Changing Air Filter Element
RESET BUTTON
CLOG INDICATOR

10.3 Cleaning / Changing Air Filter Element

Clean Replace

Every 200 hours Every 500 hours

Loosen the bolt that is holding the air cleaner and remove the cleaner cap Unscrew the wing nut and remove the filter element

Clean or replace the filter element, and reinstall it in reverse order

CLEANER CAP

WING NUT

 

 

 

CLEANER CAP

 

 

 

 

 

① FIXING BOLT

AIR CLEANER

AIR FILTER ELEMENT

 

<Caution>

￿Always make sure that the arrow mark on the cleaner cap is pointing upward

￿Clean more frequently, if used in dusty environment

￿Air filter element:

ISUZU Part No.

9142151321

￿To clean the air filter element:

￿If the element has dried contaminants, it may be cleaned by blowing compressed air from the inside.

￿If the element has carbon or grease, it should be replaced with new element.

￿Clog Indicator

The clog indicator to display clog in the air filter element is incorporated to air filter unit.

￿Whenever RED SIGNAL appears in the indicator window, clean or change element regardless of operation hour.

￿After cleaning or changing finishes, push the reset button to release the RED SIGNAL.

WINDOW (RED SIGNAL)

- 41 -

Page 41
Image 41
Shindaiwa DG1000MI manual ① ② ③, Cleaning / Changing Air Filter Element