5.1.3 Battery Charge Monitoring Lamp (charge lamp)

When the battery is unable to be charged during operation, the battery charge-monitoring lamp will flash.

Check the belt for damages or cut, and replace if needed.

<Caution>

￿For changing the belt, refer to the User Manual for Engine.

￿Battery Charge Monitor cannot detect the degradation of battery life nor the battery fluid level (refer to 8-6 Checking Battery)

5.1.4Air Filter Monitoring Lamp (clogged filter element) [DG250MI only]

!Danger

:Injuries

￿Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.

!Caution

:Burns

￿Do not touch the engine and muffler during operation and immediately after stopping the equipment, for the temperature can reach extremely high.

When the air filter element becomes dirty or clogged, the air filter monitoring lamp will flash. Turn off the engine and clean the filter element or replace if needed.

(refer to 10. Maintenance)

5.1.5Battery Fluid Monitoring Lamp (insufficient battery fluid) [DG250MI only]

!Caution

:Injuries to eyes and skin

￿Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or on clothing. If the acid comes in contact, especially with eyes, flush with a lot of water, and contact your physician immediately.

!Caution

:Fire

￿Battery may emit some combustible gas, so keep it away from fire and sparks.

- 11 -

Page 11
Image 11
Shindaiwa DG250MI, DG150MI specifications Battery Charge Monitoring Lamp charge lamp, Injuries to eyes and skin