Follow the guideline below, when performing any troubleshooting. If you cannot resolve the problems by this troubleshooting guide, contact the authorized distributor or our engineering section to request the repair.

Symptoms

Possible Cause

Corrective Actions

Starter motor does not start

1.

Weak battery

1.

Recharge battery

 

2.

Dead battery

2.

Replace battery

Engine does not start

1.

Fuel lever to CLOSE

1.

Fuel lever to OPEN

 

2.

Insufficient fuel

1.

Replenish fuel

 

3.

Water contaminants in

2.

Drain water or clean fuel

 

 

fuel

 

tank, fuel filter, and water

 

 

 

 

sedimenter

Engine starts, but stalls

1.

Insufficient oil

1.

Replenish oil

immediately

2.

Insufficient coolant/water

2.

Replenish water

 

3.

Air in the fuel system

3.

Vacuum out air

No AC output

1.

Circuit breaker is OFF

1.

Turn circuit breaker to ON

Weak AC output

1.

Wrong frequency

1.

Adjust the frequency to

 

2.

Connected equipment’s

 

match the connected

 

 

amperage exceeds the

 

equipment

 

 

rated value(Overload)

2.

Use equipment within the

 

3.

Multiple equipment

 

rated amperage

 

 

being connected

3.

Connect load to

 

 

simultaneously

 

generator one by one

 

4.

Low SPEED

4.

Increase SPEED

Voltage sharply drops when

1.

Uneven load balance

1.

Change connection

connected machines start up

 

connection

 

 

Cannot turn circuit breaker to

1.

Circuit breaker is not

1.

Push circuit breaker to

ON position

 

completely turned to

 

OFF position

 

 

OFF position

2.

Check load side

 

2.

Short-circuit on load side

3.

Repair the leakage point

 

3.

Earth leakage relay

 

 

 

 

activated

 

 

Black or white smoke is coming

1.

Overloading

1.

Reduce the load

out of exhaust pipe

 

 

 

 

successively.

 

 

 

 

 

 

 

 

 

 

 