Camera part and connector definition

5.2Connector pin definition

5.2.1Digital I/O terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

1.External alarm input-2

 

 

 

 

 

 

 

 

 

 

 

 

 

AI2

2.Becoming BW/CL enforced input when the Digital

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Mode is set to BW Mode in the Configuration-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm page

 

 

 

 

 

 

 

 

 

 

 

 

 

RS485- / +

RS485 signal output port for telemetry control

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

Alarm output port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

External alarm input-1

 

 

 

 

 

 

 

 

 

 

 

 

 

Al1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2.2 DC Auto Iris port

 

 

PIN 1

Damp -

 

PIN 2

Damp +

 

PIN 3

Drive +

 

PIN 4

Drive

5.2.3

Power IN connector

 

RED: Power +

Power: 12 V DC or 24 V AC

WHITE: Power -

5.2.4Video output connector

Video Signal Output

Composite video output

5.2.5IP/TV switch

IP

TV

Video out through Ethernet

BNC composite video out for installation purposes

5.2.6

Default/reset buttons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEFAULT

Return to factory default by pressing button for 5

 

 

 

 

seconds

 

 

 

 

 

 

 

 

 

RESET

System re-start

 

 

 

 

 

 

 

 