Siemens CCMX1315-LP configurationmanual Configuration

Models: CCMX1315-LP

1 60
Download 60 pages 19.13 Kb
Page 45
Image 45

Configuration

zScheduled Recording

Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from the recording schedule table for all days from Monday to Sunday.

zRecording by Alarm

Configure "Alarm input setting" first. Then select the recording format:

Record source: choose JPEG or MPEG4 format

Recording frame

Set the number of images to be recorded immediately after an alarm occurs. Images of the moment when an alarm occurs are not included.

1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No need for MPEG4 format

Recording cycle

Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be selected for JPEG format, no need for MPEG4 format

Recording time:

If MPEG4 is selected, please set the recording time to 2, 5, or 10 s.

zRecording by Motion

Configure "Motion Detection Setting" first.

All the other settings are same as recording by alarm as above.

NOTE

Make sure all NAS devices are ready on the network before activating this function.

 

45

 

 

Siemens Building Technologies

 

Fire Safety & Security Products

01.2009

Page 45
Image 45
Siemens CCMX1315-LP configurationmanual Configuration