Configuration

Recording Frame

Set the number of images to be recorded immediately after an alarm occurs. Images of the moment when an alarm occurs are not included.

1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No need for MPEG4 format

Recording Cycle

Set a time interval for alarm recording: 1, 2, 5, 10, 30, 60, 90, 120 s can be selected for JPEG format; no need for MPEG4 format

Recording Time:

If MPEG4 is selected, the recording time can be set to 2, 5, 10 s.

Record file name

Under transfer image section, the file name arranged by FTP server is time stamp based. With Time Stamp based, the record file name will be formatted with the desired file name, time and date as the file name. You can enter the file name or leave it blank.

zRecording by Motion

Configure "Motion Detection Setting" first.

All the other settings are same as recording by alarm as above.

FTP Server Settings - Server 1 and 2

Please follow your FTP setting to set up FTP server name, Login ID, Password,

FTP port number, FTP mode, and FTP connecting method.

 

z FTP server name: Input a server name or address.

 

z Login ID: Limited to users who have authority to access the server.

 

z Password: Input the registered password associated with the login ID.