Configuration

7.4.1External digital input 1

zSet an "Alarm Input"

ON: Detects an external alarm.

OFF: Does not perform alarm detection.

ÎThe following functions will be enabled if “ Alarm Input” is set to “ON”

zSet "Input type" for alarms

Normally Open (NO): A dry-contact detecting way, opened if nothing occurs but closed in case of an alarm.

Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but open in case of an alarm.

zSet "TEXT Enable" for alarms

A noticeable message of alarm can be displayed on screen if this item is set to “ON”.

zEnter "Text" for alarm message Max 24 characters can be entered.

zSet "Audio out" for alarm message

An audio alarm message can be sent to an external speaker if this item set to “ON”.

NOTE

A speaker with integrated amplifier can be connected to the AUDIO out jack on the rear panel.

zSelect "EVENT”

Pre-recorded voice files with extension .wav that have been uploaded to SD memory card in advance can be selected as voice alarm message. Up to 4 kinds of audio source can be selected.

7.4.2External digital input 2

All configurations are the same as for Alarm digital 1, except that an additional input mode – enforced BW – is added, which will switch the camera to monochrome mode if a trigger signal is received.

34

Siemens Building Technologies

 

Fire Safety & Security Products

01.2009

Page 34
Image 34
Siemens CCMX1315-LP configurationmanual External digital input