Configuration

Image colour

 

 

 

 

Preset image

Four types of specific application conditions such as Indoor, outdoor,

 

tunnel and casino can be selected for a quick and easy setup.

EV Adjustment

19 steps of offset level from -9 to +9 are available to adjust the internal

 

reference brightness level. The higher the level the brighter the

 

images, and the lower the level the darker the images.

Auto Gain Control

The circuit gain is adjusted automatically between Min. and the

 

selected value, "Low," "Mid" and "High” where the sensitivity

 

characteristic increases in the order of "Low," "Mid" and "High”. Noise

 

at dark will be more noticeable when Auto Gain Control is near "High".

 

NOTE:

 

 

If sensitivity is still too low after setting Auto Gain control, set the high

 

limit value of the slow shutter, to further increase sensitivity.

Shutter Speed

Default is: 1/25 s. The shutter speed is set at automatic, 1/25 s, 1/50 s,

 

1/120 s, 1/250 s, 1/1000 s and 1/10000 s. The network camera will

 

adjust the aperture according to the amount of ambient light.

Slow Speed Shutter

The Slow shutter can be turned “ON” if the sensitivity is still not so

 

good under “High” gain condition at dark. The optimum image level can

 

be maintained by appropriate gain and shutter combination which are

 

determined automatically inside camera system.

 

As slow shutter activates, the exposure time becomes longer and

 

frame rate becomes smaller. Blurred images sometimes are prominent

 

with moving objects.

Back Light Compensation

Set an area for backlight compensation. If backlight compensation is

 

activated, the camera performs the exposure control only within the

 

specified area.

 

Backlight compensation is a function that achieves the brightness of a

 

selected area to an optimum image level. This function is necessary

 

when an auto iris lens tends to close due to an intense light coming

 

from the back of the object in the area to be viewed so that areas

 

become dark and visibility deteriorates. In this case, set the area so

 

that the portion to be viewed is within the selected area. The area size

 

is roughly as shown in Fig. 2 below.

Sharpness

Set sharpness.

 

“Sharp”:

sharpness is high.

 

“Soft”:

sharpness is low.

Gamma

“1”: May be selected for some specific area, such as FA application for

 

obtaining true video data.

 

“0.45”: This is default, suitable for CCTV application

White Balance

Set the white balance values to meet the environment condition for

 

best colour rendition.

 

z “AWB”: the colour of the camera is automatically adjusted according

 

to external lighting condition.

 

z “Manual”: Adjustable by user manually, this is useful for some

 

specific condition which AWB may be unaffordable to perform

 

correctly.

 

z “Indoor”: Default for 3200K condition

 

z “Outdoor”: Default for 5100K condition

Iris Adjustment

19 steps of offset level from -9 to +9 are available to adjust the image

 

level for a DC auto iris lens. The higher the level the brighter the

 

images, and the lower the level the darker the images.

 

29

 

 

Siemens Building Technologies

 

Fire Safety & Security Products

01.2009

Page 29
Image 29
Siemens CCMX1315-LP configurationmanual Image colour