Simrad H1000 manual Clutch voltage selection

Models: H1000

1 68
Download 68 pages 5.92 Kb
Page 34
Image 34

h1000 pilot

 

description/installation

 

 

 

clutch voltage selection

The h1000 pilot computer unit can output different clutch/solenoid voltages depending upon the size of rudder drive unit fitted. The clutch/solenoid valve is only required for rams or rotary drive units. This is achieved by setting dip-switches on the computer drive PCB. Access to the switches is obtained by removing the four screws holding the computer PCB into the lid of the computer unit and then carefully lifting the PCB clear.

Set the switches as per the table below. The default setting is 9V, switch 4 ON, which is suitable for Size 0, 1, and 2 12V rams.

Dip Switch

Clutch Voltage

Drive Size / Type

1

24V

24V Rotary

2

18V

Size 2 and 3, 24V Rams

3

12V

12V Rotary

4

9V

Size 0, 1 or 2 12V Rams