h1000 pilot

 

description/installation

 

hydraulic drive pumps

description

The reversible hydraulic drive pump has a small high-speed pump driven by a 12V or 24V dc permanent magnet motor. The pump has pilot check valves to prevent back driving and a pilot operated reservoir valve to enable the unit to drive balanced or unbalanced cylinders. The unit has port and starboard

¼ inch BSP service ports and a ¼ inch BSP reservoir port.

pump data

Hydraulic Pump Type

PMP-T1-12V

PMP-T2-12V

PMP-T3-24V

Pump Type

Reversible

Reversible

Reversible

 

dc motor

dc motor

dc motor

Supply Voltage

12V dc

12V dc

24V dc

Typical Operating Current

5A to 17.5A

5A to 22.5A

6A to 17.5A

Range

 

 

 

Maximum Pressure

1000 psi

1000 psi

1000 psi

Maximum Flow Rate

750 cc/min

1420 cc/min

1980 cc/min

at continuous duty motor

(46 in3/min)

(87 in3/min)

(121 in3/min)

loading

 

 

 

Cylinder Capacity

100cc to 300cc

275cc to 550cc

525cc to 750cc

 

(6.1 to 18.3 in3)

(16.8 to 33.6in3)

(32 to 46in3)

Weight

3 kg

3 kg

4 kg

 

(6.6 lbs)

(6.6 lbs)

(8.8 lbs)

key points on installation

ξ A position should be chosen convenient for the steering system hydraulic delivery lines. ξ The site should be rigid and flat to prevent excess vibration.

ξ Shielded from the direct effects of the elements.

ξ Minimise the lengths of the hydraulic lines from the pump to the cylinder and where possible, the pump motor supply cables.