h1000 pilot

calibration

seatrial calibration

The following parameters should be set and checked during the initial sea trial.

ξ Compass Swing ξ Rudder Amidships ξ Boat Lag

ξ Rudder Gain

The sea trial calibration should be carried out in open water on a calm day. The procedures for the remainder of the calibration involve continual course and speed changes. It is very important to maintain a constant lookout at all times. Use proper seamanship when clearing turns to ensure the calibration is carried out safely.

The autopilot will be initially operating from the factory default values for boat lag and rudder gain. During the sea trial the pilot learning algorithm will automatically set and adjust the value for rudder gain. The values for boat lag and rudder gain will be checked and adjusted to finely tune the autopilot steering performance when necessary. The default values are automatically set depending upon the type of vessel selected under boat type.