SMC Networks TigerSwitch manual Shutdown, Following example enables flow control on port

Models: TigerSwitch

1 518
Download 518 pages 30.84 Kb
Page 393
Image 393

Command Usage

Flow control can eliminate frame loss by “blocking” traffic from end stations or segments connected directly to the switch when its buffers fill. When enabled, back pressure is used for half-duplex operation and IEEE 802.3x for full-duplex operation.

To force flow control on or off (with the flowcontrol or no flowcontrol command), use the no negotiation command to disable auto-negotiation on the selected interface.

When using the negotiation command to enable auto-negotiation, the optimal settings will be determined by the capabilities command. To enable flow control under auto-negotiation, “flowcontrol” must be included in the capabilities list for any port

Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub.

Example

The following example enables flow control on port 5.

Console(config)#interface ethernet 1/5

Console(config-if)#flowcontrol

Console(config-if)#no negotiation

Console(config-if)#

Related Commands

negotiation (4 -148)

capabilities (flowcontrol, symmetric) (4-149)

shutdown

This command disables an interface. To restart a disabled interface, use the no form.

Syntax

[no] shutdown

Default Setting

All interfaces are enabled.

4-151

Page 393
Image 393
SMC Networks TigerSwitch Shutdown, Following example enables flow control on port, Syntax No shutdown Default Setting