Displaying the digital hours meter

Use the following procedure.

1 Press the MENU button on the menu control panel.

The menu selection level display appears on the monitor screen and in the time counter display.

Menu selection level display

 

 

 

SYSTEM MENU

 

Setup menu

 

 

SETUP MENU

AUTO FUNCTION

 

Time counter display

HOURS METER

 

 

 

 

 

 

Monitor screen

2 Press the j button to select “HOURS METER.”

SYSTEM MENU

 

Hours meter

SETUP MENU

 

AUTO FUNCTION

 

Time counter display

 

 

HOURS METER

 

 

 

 

 

Monitor screen

3 Press the k button.

The cumulative counts by the digital hours meter are indicated on the monitor screen and in the time counter display.

Troubleshooting and Maintenance 6 Chapter

Digital hours meter indications on the monitor screen

All four counts (T1, T2, T3, and CT) are indicated on the monitor screen.

Resettable trip counts

Unresettable counts

HOURS METER

T1 00000 X10 HOURS

T2 0000/00000 X10 HOURS

T3 0000/00000 X10 HOURS

CT 0000/00000 X10 COUNT

T1:OPERATION

T2:DRUM ROTATION

T3:TAPE RUNNING

CT:THREADING

The four-digit value to the left of the slash (/) is the resettable trip count, and the right value is the cumulative total from manufacture.

Digital hours meter indications in the time counter display

One of the four indications appears in the time counter display at a time. Use the J and j buttons on the menu control panel to change the item displayed.

Initially, only the trip value appears. Hold down the k button to display also the cumulative total from manufacture, which will appear to the right of the trip value and the slash (/).

The following illustrates the digital hours meter indications in the time counter display in all four display modes. The right-hand indication for each display mode is the indication you can view while holding down the k button on the menu control panel.

T1 (OPERATION) mode:

Oper. 00000

T2 (DRUM ROTATION) mode:

Drum 0000

 

0000/00000

T3 (TAPE RUNNING) mode:

Tape 0000

 

0000/00000

CT (THREADING) mode:

Thread 0000

 

0000/00000

92 Maintenance