13Store the ND offset values in the OHB file, by executing STORE FILE on the <OHB FILE> page of the FILE menu.

Note

Be sure to accurately adjust to the video level you noted in step 5. If the level is not obtained through the iris adjustment of the lens, use the shutter function or the master gain adjustment.

To use the ND offset values

An appropriate offset value is automatically retrieved when you change the ND filter setting.

To initialize the ND offset values

Perform ND OFFSET on the <OHB FILE> page (subpage of the <FILE PRESET> page of the FILE menu).

To reset the data of the OHB fileIn a case of the OHB file, resetting can be performed by item.

Position the pointer to OHB FILE then push on the MENU SEL/ENTER dial. The <OHB FILE PRESET> page will be displayed.

<OHB FILE PRESET>

ESC

cWHITE SHADING(ALL) 3D WHITE SHADING BLACK SHADING BLACK SET

NO OFFSET MATRIX

Position the pointer to the item you wish to reset then push on the MENU SEL/ENTER dial.

5-3-8 Resetting to the Initial Settings

With the <FILE PRESET> page of the FILE menu, data in the modified files or the configuration of the edited USER menu can be reset to the initial settings, by type of files or collectively.

<FILE PRESET>

F07 TOP

cOPERATOR

FILE

USER

GAMMA

FILE

LENS

FILE(ALL)

No.: 1 CLEAR: EXEC

REFERENCE

FILE

10

SEC

CLEAR: OFF

OHB

FILE

 

 

USER

MENU

 

 

M.S.

FORMAT

 

FILE

PRESET

(-OHB)

 

 

 

 

To reset data of files by type of filesTo reset data of the operator file, User-Gamma file, and reference file

Position the pointer to the corresponding line then push on the MENU SEL/ENTER dial.

The data in the corresponding file in built-in memory will be reset to the initial settings.

The configuration of the USER menu can be reset in the same manner.To reset data of the lens files

To reset data of all lens files, position the pointer to LENS FILE (ALL) and push on the MENU SEL/ ENTER dial.

To reset data of a specific lens file, assign the file number in the No. column and push on the MENU SEL/ENTER dial to position the pointer to the CLEAR column. Then push on the MENU SEL/ENTER dial again.

To reset a specific item in the reference file to the initial settingThe items in the reference file can be reset individually.1 On the <FILE PRESET> page, set 10 SEC CLEAR to ON.

2 Shift to the menu page on which the item you wish to reset is located. Position the pointer to the item you wish to reset then hold the MENU SEL/ENTER dial pressed.

Continue to hold the MENU SEL/ENTER dial pressed after the pointer changes to a question mark (?). After about 3 seconds, the current setting of the corresponding item will be reset to the initial setting, and “CLEARED” will be displayed.

If the dial is continuously held pressed, after about additional 7 seconds, the setting of the corresponding item that is stored in the reference file will be reset to the initial setting, and “REF CLEARED” will be displayed.

To reset the files and settings collectively

All files except the OHB file can be reset simultaneously. Position the pointer to FILE PRESET (–OHB) on the <FILE PRESET> page then push on the MENU SEL/ ENTER dial. The message “POWER OFF TO SET” will be displayed. Set the POWER switch of the camera to OFF.

Data Setting User of Retrieval and Storage 5 Chapter

File Operations 95