MAINTENANCE menu

Page title &

No.

Item

Default

Settings

Remarks

purpose

 

 

 

 

 

 

 

 

 

 

 

<OUTPUT

M07

CURRENT

23.98PsF 4:4:4

 

The current format is

FORMAT>

[M03]

 

 

 

displayed.

Setting the output

 

SCAN

PROGRESSIVE

PROGRESSIVE,

When INTERLACE is

video format

 

 

 

INTERLACE

selected for SCAN, select

 

 

FRAME

23.98

23.98, 24, 25, 29.97, 30,

half the value of the field

 

 

 

 

50, 59.94, 60

frequency in FRAME.

 

 

 

 

 

 

 

SIGNAL

4:4:4 RGB

4:4:4 RGB, 4:2:2 YCbCr

 

 

 

SELECT FPS

OFF

ON, OFF

 

 

 

SET FORMAT

 

Execute by ENTER.

 

<DOWN

M08

ASPECT

LB

SQ, LB, EC

SQ: Squeeze

CONVERTER>

[M04]

 

 

 

LB: Letter Box

Setting the aspect

 

 

 

 

EC: Edge Crop

 

 

 

 

 

ratio for VBS output

 

 

 

 

 

<POWER SAVE>

M09

MONITOR OUT

ACTIVE

PWR SAVE, ACTIVE

 

Selecting the output

[M05]

DOWN CONVERTER

ACTIVE

PWR SAVE, ACTIVE

 

power save mode

 

 

 

 

 

<BATT ALARM

M10

DC IN (24 V)

 

 

 

SET>

[M06]

 

 

 

 

TYPE

AC ADP

BATT1, BATT2, AC ADP

BATT1/BATT2: Batteries

 

 

Setting the voltage

 

 

 

 

AC ADP: AC adaptor

values to trigger

 

NEAR END

22.2 V

0.1 to 30.0 V

Fixed to the default value

alarm indications

 

 

 

 

 

for AC ADP

 

 

 

 

 

 

 

END

21.6 V

0 to 29.9 V

Fixed to the default value

 

 

 

 

 

for AC ADP

 

 

DC IN (12 V)

 

 

 

 

 

TYPE

AC ADP

BATT1, BATT2, AC ADP

BATT1/BATT2: Batteries

 

 

 

 

 

AC ADP: AC adaptor

 

 

NEAR END

11.1 V

11.0 to 17.0 V

Fixed to the default value

 

 

 

 

 

for AC ADP

 

 

END

10.8 V

10.5 to 14.0 V

Fixed to the default value

 

 

 

 

 

for AC ADP

<GENLOCK>

M11

REFERENCE

 

INTERNAL, GENLOCK

display only

Adjusting Genlock

[M07]

 

 

IN

 

with status

 

STATUS

 

OK, NG, NO SIGNAL

display only

indications

 

H PHASE

0

–511 to 511

To adjust the H phase for

 

 

 

 

 

 

 

genlock

<DATE>

M12

DATE/TIME

 

yyyy/mm/dd

 

Setting the built-in

[M08]

 

 

hh : mm

 

 

 

 

 

 

clock

 

 

 

 

 

 

 

 

 

 

 

Settings Detailed and Configuration Menu 4 Chapter

Menu List 75