8-3 UMID Output and Display
This section explains how to output and display | To switch the displayed UMID item in the | |
UMIDs. | menu display section | |
|
| Rotate the MULTI CONTROL knob. |
Note |
|
|
When the number of active scan lines for HD SDI | To exit from UMID display | |
output is set to 720P, output and displaying of UMID | Press the F6 (EXIT) button. | |
are not carried out. |
|
Functions UMID 8 Chapter
You can choose to output UMIDs or not, and select either Basic UMID or Extended UMID when you choose to output UMIDs. Make these settings using setup menu item 651 UMID OUTPUT.
(UMID information is added to HD SDI output.)
See page
During recording and playback, UMID data appears in the menu display section of the control panel and on the video monitor.
To display the UMID
In function menu page 5, press the F2 (UMID) button.
See Section
The UMID appears in the menu display section of the control panel and on the video monitor.
First item in UMID displayed in menu display section
UMI | INSTANCE 24PRS |
|
|
| ||
D |
|
|
|
|
| EXIT |
HOME | F1 | F2 | F3 | F4 | F5 | F6 |
See the next section “UMID display on the video monitor” for examples of the UMID displayed on the video monitor.
UMID display on the video monitor
The video monitor connected to the COMPOSITE VIDEO OUTPUT 3 (SUPER) connector or the SDI OUTPUT 3 (SUPER) connector on the connector panel displays all UMID items at once. The display of each line is explained below.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| UMID INFORMATION |
|
|
| |||||||||
| INSTANCE 24PRS |
|
|
|
|
| 1 | ||||||
|
|
|
|
|
| ||||||||
| MATERIAL SMPTE |
|
|
|
|
|
|
|
| 2 | |||
|
|
|
|
|
|
|
|
| |||||
|
|
|
| 3 | |||||||||
|
|
| |||||||||||
|
|
|
|
| |||||||||
|
|
|
|
|
| ||||||||
| DATE/TIME 20XX/XX/XX |
|
|
| 4 | ||||||||
| XX:XX:XX:XX +XX:XX |
|
|
|
|
|
| ||||||
|
|
|
|
| |||||||||
| ALTITUDE XXXXXXXXm |
|
|
|
|
|
|
| 5 | ||||
|
|
|
|
|
|
| |||||||
| LONGITUDE EXXX XX'XX.XX |
|
|
|
|
| 6 | ||||||
|
|
|
|
|
| ||||||||
| LATITUDE | SXXX XX'XX.XX |
|
|
|
|
| 7 | |||||
|
|
|
|
|
| ||||||||
| ORGANIZATION XXXX |
|
|
|
|
|
| 8 | |||||
|
|
|
|
|
|
| |||||||
| USER XXXX | COUNTRY XXXX |
|
|
| 9 | |||||||
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1Instance Number generation method and Instance Number
The generation method is displayed as follows. CP+16:
+Copy No.” method 24PRS:
When menu item 656 MATERIAL NO. is set to NEW, the SMPTE method is used.
2Material Number generation method SMPTE: SMPTE method
IEEE 1394 ZONE: IEEE 1394 ZONE method
IEEE 1394 RND: IEEE 1394 RND method
others: Other than the above
3Material Number
The material number is displayed in hexadecimal across two lines.
The following items, 4 through 9, are contained in the Source Pack.