(3)View the test page from directly in front, and select the cell that is closest to the neutral gray.

Place five sheets of white plain paper under the printed test page so that no background color or pattern shows through the test page.

Easy Calibration TestPage

X

1 2 3 4 5 6 7 8 9 10 11

WEB PAGE (ADMINISTRATOR)

Color Balance

This function is used to adjust each of the density levels (low, mid, and high) of the four color components, cyan, magenta, yellow and black.

Use this mode when the color deviation is significant. Before using the Color Balance, load 8-1/2" x 11" or A4 white plain paper in the tray and follow the instructions in "Environmental conditions for color adjustments" (page 3-55).

(1)Access the machine's Web page from your computer and open the Color Adjustments page.

11

10

If you desire this color of

9gray, the coordinates are

8

X = 3, Y = 8.

 

7

Y 6

5

4This shows the current

3value of the Easy

2Calibration setting.

1

The test page is divided into cells with 11 on the horizontal axis (X) and 11 on the vertical axis (Y). Each cell is filled in with gray mixed with a varied hue of color.

(4)Enter the coordinates of the color selected in step (3) in [X] and [Y] of the Easy Calibration and click the [Submit] button.

If the color adjustment is not satisfactory on the trial print, repeat the above procedure (1) to (4). If the color is still not satisfactory after repeating the procedure several times, use the "Color Balance".

(2)Click the [Test Print] button in the Color Balance.

A test page for the Color Balance is printed.