Menus 8 Chapter

Menu items in the 700s, relating to video control

Item number

Item name

 

Settings

 

 

 

 

723

INPUT VIDEO BLANK

Switch blanking on or off for individual lines in the vertical blanking interval

 

 

 

of an input video signal. The Y/C signal and odd/even fields are blanked

 

 

 

simultaneously.

 

Sub-item

 

A signal with blanking carried out according to this setting is recorded.

 

 

 

 

 

 

0

ALL LINE

- - -: Specify the blanking for each line separately.

 

 

 

blnk: Regardless of the setting of other sub-items, blank all lines which

 

 

 

 

can be specified in this menu item.

 

 

 

thru: Regardless of the setting of other sub-items, switch off blanking for

 

 

 

 

all lines which can be specified in this menu item.

 

 

 

 

 

In 525(U)/

12 ... 20

LINE 12 ... LINE 20

Specify blanking for lines 12 to 20.

525(J)-line

 

 

blnk: Carry out blanking.

modes

 

 

thru: Switch off blanking.

 

 

 

 

 

In 625-line

9 ... 22

LINE 9, 322 ...

Specify blanking for lines 9 to 22.

mode

 

LINE 22, 335

blnk: Carry out blanking.

 

 

 

thru: Switch off blanking.

 

 

 

 

 

726

H BLANKING WIDTH

Select the horizontal blanking width of the video output signal.

 

 

 

narow: Digital blanking (narrow)

 

 

 

wide: Analog blanking (wide)

 

 

 

When “wide” is selected, the horizontal blanking width complies with

 

 

 

RS170A, and normally the blanking is widened and the image becomes

 

 

 

narrower. It is recommended to select “narow” at the editing stage, then

 

 

 

later, for broadcast transmission to select “wide,” to output a signal

 

 

 

conforming to the standard. Note, however, that “narow” has to be always

 

 

 

selected for SDI signals.

 

 

 

 

728

OUTPUT SCH PHASE

Set the subcarrier H phase.

 

 

 

–512 to 0 to 511

 

 

 

 

 

 

 

Menu items in the 800s, relating to audio control

 

 

 

 

 

Item number

Item name

 

 

Settings

 

 

 

 

802

DIGITAL AUDIO MUTING IN

 

Set the audio muting conditions during shuttle playback.

 

SHUTTLE MODE

 

off: Not muted.

 

 

 

 

on: Muted.

 

 

 

 

807

AUDIO OUTPUT PHASE

 

Set the output timing of digital output signals (SDI, AES/EBU only), with

 

 

 

 

80H as a reference position. Output timing is earlier for values smaller

 

 

 

 

than 80H and later for values greater than 80H. (80H, 128 samples =

 

 

 

 

approx. 2.7 ms, 80H, 1 sample = approx. 20 S

 

 

 

 

0 to 80 to FF: Values can be set in this range.

 

 

 

 

808

INTERNAL AUDIO SIGNAL

 

Select the operation of the internal audio test signal generator.

 

GENERATOR

 

silnc: Silent signal.

 

 

 

 

1kHz: 1 kHz, -20 dB FS sine wave signal.

 

 

 

 

When you select SG as the audio input in the input selection section of

 

 

 

 

the control panel, the audio test signal generated by the internal audio

 

 

 

 

test signal generator is input.

 

 

 

 

815

AUDIO SAMPLING RATE

 

Select the mode of operation of the sampling rate converter for AES/

 

CONVERTER

 

EBU input to channels 1 to 4.

 

 

 

 

off: No operation

 

 

 

 

on: Operate.

 

 

 

 

 

100 8-3 Extended Menu