Menu items in the 600s, relating to the time code, metadata, and UMID

Item number

Item name

Settings

 

 

 

 

607

U-BIT BINARY GROUP FLAG

 

Select the user bits to be used in the time code generated by the time

 

 

 

code generator.

 

 

 

000: Character set not specified.

 

 

 

001: 8-bit characters compliant with ISO 646 and ISO 2022.

 

 

 

010: Undefined.

 

 

 

011: Undefined.

 

 

 

100: Undefined.

 

 

 

101: SMPTE 262M page/line multiplex system.

 

 

 

110: Undefined.

 

 

 

111: Undefined.

 

 

 

 

611

TC OUTPUT PHASE IN EE MODE

 

Select the time code output mode for output from the TIME CODE OUT

 

 

 

connector in E-E mode.

 

 

 

mutng: Mute the output.

 

 

 

thru: Output the time code input to the TIME CODE IN connector as it is.

 

 

 

v-in: Output the time code with the same phase as the input video signal

 

 

 

phase.

 

 

 

v-out: Output the time code with the same phase as the output video

 

 

 

signal phase.

 

 

 

 

612

TC OUTPUT MUTING IN SEARCH

 

Select whether to mute the output from the TIME CODE OUT connector

 

MODE

 

in jog/shuttle mode.

 

 

 

on: Mute.

 

 

 

off: Do not mute.

 

 

 

 

619

VITC

 

Specify whether or not to record the VITC generated by the internal time

 

 

 

code generator.

 

 

 

off: Do not record internally generated VITC.

 

 

 

on: Record internally generated VITC.

 

 

 

 

 

 

 

 

Note

 

 

 

Even

if this item is set to “off,” VITC is recorded if the input video signal

 

 

 

contains VITC and the VITC line is set to “thru” with item 723.

 

 

 

626

TC MODE

Select the time code recording mode.

 

 

 

int preset: Set an initial value, then record the output of the internal time

 

 

 

code generator.

 

 

 

int regen: Record the output of the internal time code generator,

 

 

 

initialized to time code following continuously upon the time code of

 

 

 

the last frame of the last clip on the disc.

 

 

 

ext regen: Record the output of the internal time code generator,

 

 

 

synchronized to an external time code generator.

 

 

 

rp188 regen: Record the output of the internal time code generator,

 

 

 

synchronized to SMPTE RP188 LTC in an SDI signal.

 

 

 

ext preset: Directly record the input of an external time code generator.

 

 

 

See 4-1-2 “Recording Time Code and User Bit Values” (page 50) for

 

 

 

more information about time code recording modes.

 

 

 

627

RUN MODE

When item 626 is set to “int preset,” select the run mode of the internal

 

 

 

time code generator.

 

 

 

free run: Time code advances continually.

 

 

 

rec run: Time code advances only during recording.

 

 

 

 

628

DF MODE

 

In 525(U)/525(J)-line modes, when item 626 is set to “int preset,” select

 

 

 

the run mode of the internal time code generator and counter.

 

 

 

on (df): Drop-frame mode

 

 

 

off (ndf): Non-drop frame mode

 

 

 

 

629

TC SELECT

 

Select the type of time data to show in the time data display, and the type

 

 

 

of external time code when item 626 is set to “ext regen.”

 

 

 

vitc: Display time code as VITC, or select VITC as the external time

 

 

 

code.

 

 

 

tc: Display time code as TC, or select TC as the external time code.

 

 

 

See 4-1-2 “Recording Time Code and User Bit Values” (page 50) for

 

 

 

more information about selecting external time code.

 

 

 

 

 

Menus 8 Chapter

8-3 Extended Menu 97