Menus 8 Chapter

Menu items in the 600s, relating to the time code, metadata, and UMID

Item number

Item name

 

 

Settings

 

 

 

 

 

651

UMID SDI OUTPUT

 

Select whether to output UMID in the VANC of the SDI output.

 

 

 

 

off: Do not output.

 

 

 

 

on: Output.

 

 

 

 

See 8-3-3 “Using UMID Data” (page 104) for more information about

 

 

 

 

UMID.

 

 

 

 

 

652

UMID SDI VANC LINE

 

Select the line in which UMID is output when menu item 651 is set to “on.”

 

 

 

 

12H, 13H, 15H, 16H, 17H, 18H, 19H (525(U)/525(J)-line modes)

 

 

 

 

9H, 10H, 12H, 13H, 14H, 15H, 16H, 17H, 18H (625-line mode)

 

 

 

 

See 8-3-3 “Using UMID Data” (page 104) for more information about

 

 

 

 

UMID.

 

 

 

 

 

657

ESSENCE MARK SDI OUTPUT

 

Select whether to output essence marks in the SDI output VANC.

 

 

 

 

off: Do not output.

 

 

 

 

on: Output.

 

 

 

 

 

660

ESSENCE MARK SDI VANC LINE

 

When item 657 is set to “on”, select the line to which to output essence

 

 

 

 

marks.

 

 

 

 

12H, 13H, 15H, 16H, 17H, 18H, 19H (525(U)/525(J)-line modes)

 

 

 

 

9H, 10H, 12H, 13H, 14H, 15H, 16H, 17H, 18H (625-line mode)

 

 

 

 

 

 

 

Menu items in the 700s, relating to video control

 

 

 

 

Item number

Item name

 

Settings

 

 

 

701

SELECTION OF VIDEO/SYNC

An E-E video signal is output delayed with respect to the video input signal

 

DELAY

 

by the time for video circuit processing.

 

 

 

With this item, select whether or not to delay the sync signal attached to

 

 

 

the output video signal by an amount corresponding to the video signal

 

 

 

delay.

 

 

 

sync: Delay the sync signal by the corresponding amount before attaching

 

 

 

 

it.

 

 

 

video: Attach a sync signal with the same timing as the input signal.

 

 

 

703

BLANK LINE SELECT

Switch blanking of the video output signal on or off for individual lines in the

 

 

 

vertical blanking interval.

 

Sub-item

 

 

 

The Y/C signal and odd/even fields are blanked simultaneously.

 

 

 

 

 

 

 

 

0

ALL LINE

- - -: Specify the blanking for each line separately.

 

 

 

blnk: Regardless of the setting of other sub-items, blank all lines which

 

 

 

 

can be specified in this menu item.

 

 

 

thru: Regardless of the setting of other sub-items, switch off blanking for

 

 

 

 

all lines which can be specified in this menu item.

 

 

 

 

In 525(u)-line

12 ... 19

LINE 12 ... LINE 19

Specify blanking for lines 12 to 19.

mode

 

 

blnk: Carry out blanking.

 

 

 

thru: Switch off blanking.

 

 

 

 

 

20

LINE 20

Specify blanking for line 20.

 

 

 

blnk: Carry out blanking.

 

 

 

half: Carry out half-blanking.

 

 

 

thru: Switch off blanking.

 

 

 

 

In 525(J)-line

12 ... 20

LINE 12 ... LINE 20

Specify blanking for lines 12 to 20.

mode

 

 

blnk: Carry out blanking.

 

 

 

thru: Switch off blanking.

 

 

 

 

 

21

LINE 21

Specify blanking for line 21.

 

 

 

blnk: Carry out blanking.

 

 

 

half: Carry out half-blanking.

 

 

 

thru: Switch off blanking.

 

 

 

 

 

98 8-3 Extended Menu