Locations and Functions of Parts

Iris/master black control block (RCP-D51)

4IRIS RELATIVE button 5IRIS/M.BLACK LINK button

1MASTER BLACK display

 

 

6f-number display

 

 

EXT

7EXT indicator

2MASTER BLACK control

 

 

8SENS control knob

MASTER

 

 

9COARSE control knob

BLACK

RELATIVE IRIS/

SENS

CLOSE OPEN

 

 

M.BLACK

 

COARSE

 

LINK

 

 

3IRIS/M.BLACK ACTIVE button

 

 

 

IRIS/M.BLACK

AUTO

 

 

ACTIVE

 

 

 

 

 

 

0IRIS control

 

 

 

qaIris gauge

 

 

 

IRIS

 

qsAUTO button

 

 

1MASTER BLACK display

Displays the current master black setting in the range from –99 to +99.

2MASTER BLACK control Manually adjust the master black level.

The setting is displayed in the MASTER BLACK display.

3IRIS/M.BLACK ACTIVE (iris/master blackactive) button

Press and light up this button to enable the iris/master black control block of the panel.

When the PANEL ACTIVE button is pressed, this button also lights.

If you press this button so that it goes dark, the panel will be locked, preventing accidental misoperation.

4IRIS RELATIVE (iris relative) button

When the IRIS/M.BLACK ACTIVE button is lit, the iris adjustment mode can be selected with this button. Press and light up the button for Relative mode or press so that it goes dark for Absolute mode.

When the IRIS/M.BLACK ACTIVE button is not lit, Relative mode is automatically selected and this button is not operative.

Note

When VR STD MODE is set to Absolute with “VR Setting” of the RCP Config menu, Relative mode is not selected even if you turn the IRIS/M.BLACK ACTIVE button off. When you turn the IRIS/ M.BLACK ACTIVE button on, the iris setting corresponding to the position of the IRIS control is restored.

5IRIS/M.BLACK LINK (iris/master black adjustment link) button

Press and light up the button to perform linked adjustments of iris and master black for several cameras.

For details, see “Adjusting the Iris/Master Black of Multiple Cameras at One Time” on page 57.

6f-number display

Displays the f number of the current iris setting. When the iris is closed, “CL” is displayed.

When the DXC-D50 series is connected, “OP” is displayed for the maximum f-number value.

7EXT (lens extender) indicator

Lights when the lens extender is used.

12