In a
If the selected unit is set as the master unit and the rest are set as slave units, the setting data of the camera connected to the master unit can be transferred to other cameras.
To make connections among theConnect
For more information about cables which can be used, consult your Sony dealer.
Notes
•It is impossible to assure that all the cameras can be set up to the same conditions under the
•In a system which contains more than two types of cameras, the setting items, adjustment range and adjustment accuracy available at the
•There are two setting modes: Absolute mode and Relative mode.
•Settings performed on a slave unit are valid only to the connected camera.
Setting a unit to the master unit or a slave unitNote
Perform the following procedure after making sure all the cameras in the system are powered on. Note that executing the procedure when there is any cameras powered off may result in failure.
1 Select one RCP unit for the master unit, and press the MASTER button. (The button lights when pressed.)
2 Select one RCP unit (or more) for a slave unit, and press the SLAVE button. (The button lights when pressed.)
For iris and master black adjustments, you can use any one of the RCP units (whether it is the master unit or a slave unit) specified with the IRIS/M.BLACK LINK button.
1 Select the cameras for which you will adjust the iris or master black by pressing the IRIS/ M.BLACK LINK buttons on the connected RCP units. (The buttons light when pressed.)
2 Adjust the iris or master black on one RCP unit whose IRIS/M.BLACK LINK button lights.
On the cameras connected to the RCP units whose IRIS/M.BLACK LINK buttons light, the iris or master black adjustments are performed by the same amount and at the same time (on relative mode).
Note
The IRIS/M.BLACK LINK function is released while transferring the scene files.
Data Transfer Among MultipleCamerasThe settings made on the master unit can be transferred to the cameras connected to the slave units, if they can be registered as a scene file.
Perform as follows:
1 Select [File] from the OTHERS menu, and press [Copy to Slaves].
2 Press [Start].
Data transfer begins.
Meanwhile, on all the linked RCP units (including units selected as neither the master unit nor slave units), the message “IN PROGRESS” is displayed on the LCD and all buttons and knobs are locked.
When the data transfer completes, the message “COMPLETED” appears on the LCD. The LCD soon returns to the original status.