Camera the Administrating
Select the initial frame rate which is selected when you log in the camera and display the main viewer page. Click the
The selectable frame rates are the following:
1, 2, 3, 4, 5, 6, 8, 10, 15, 20, 25, Fastest
1, 2, 3, 4, 5, 6, 8, 12, 16, 20, Fastest
The numbers indicate “FPS” (the number of frames transmitted per second).
With Fastest, the camera transmits the maximum number of frames possible for the connected line. The maximum frame rate is 30 FPS for the
Note
To update the main viewer page for the changed setting, click Refresh of the browser.
Default URLSelect the homepage to be displayed when you enter the IP address of the camera in the Address box of the browser.
To display the homepage built in the camera
Select /index.html.
To display your individual homepage
You can display the favorite homepage that you have created using the CGI commands of the camera. Store the created HTML file in the recommended ATA memory card and insert the card into the PC card slot of the camera, or store the HTML file in the
1 Select User Setting.
2 Store the HTML file of the homepage you created into an ATA memory card and insert the card into the PC card slot of the camera. Or, store the HTML file in the
For use of the Custom Homepage Installer, see page 51.
3 Select /adrv/ when using the ATA memory card, or /ddrv/ from the
4 Type the path of the homepage in the text box up to 64 characters.
Displays the type of the PC card inserted into the PC card slot and its free card space.
Flash memory (ddrv)
Displays the file size stored in the
Limits the operation of the camera
If you select Off, multiple users can operate the camera at the same time. The operation by the user accessed later has priority.
If you select On, only one user can operate the camera. The period of operation allowed to one user is determined by the Operation time setting. If a user tries to operate the camera while another user is operating it, the control right is limited according to the Operation time and Maximum wait number settings.
Operation time
Sets the period that one user can operate the camera exclusively, between 10 and 600 sec.
This setting is valid when the Exclusive control mode menu is set to On.
Maximum wait number
Sets the maximum number of users that can wait to control the camera while another user is operating the camera. The selectable number is between 0 and 20. This setting is valid when the Exclusive control mode menu is set to On.
Notes
•Before using the Exclusive control mode, you need to set the date and time correctly on this camera and the connected computer.
•When you use the Exclusive control mode, enable the Cookie on your browser. The Exclusive control mode does not function if the Cookie is disabled.
•After you have changed a setting of the Exclusive control mode menu, click Refresh of the browser to update for the changed setting.
System logClick View to display the Log file events page.
The Log file events page shows the software version and troubleshooting information.
Access logClick View to display the Access log page.
The Access log page shows the history of accessing the camera.
18 Configuring the System — System setting Page