Chapter 3. Installing Camera & Network Setup
3.1. PTZ Dome Camera and Accessory Wiring Diagrams |
3.2. DIP Switch Settings
Connecting to the NVR |
IP Camera
Local Area
| SW1 |
|
|
| SW2 |
|
| SW3 |
| ||||
ON |
|
|
|
| ON |
|
|
|
| ON |
|
|
|
1 | 2 | 3 | 4 |
| 1 | 2 | 3 | 4 |
| 1 | 2 | 3 | 4 |
|
|
| ON |
|
|
|
| ON |
|
|
|
|
|
|
|
| 1 | 2 | 3 | 4 |
| 1 | 2 | 3 | 4 |
|
|
|
|
|
| SW4 |
|
|
| SW5 |
|
|
|
SW (Pin No.) | Purpose |
SW1(1~4) | Protocol Settings |
SW2(1~2) | Baud Rate Settings |
SW2(3) | Transfer Method Settings |
SW2(4) | Response Mode Settings |
SW3(1) | TBD |
SW3(2~3) | Termination Settings |
SW3(4) | TBD |
SW4, SW5 | Camera ID Setup |
Network
SNR- |
6400/3200 |
Connecting directly to the SCC-3100A controller
· | ||
Data Box Port 1 | ||
|
| RX+ |
| |
Camera | RX- | ||
D+ | TX+ | ||
D- | TX- |
| |
Data | |||
Camera | Data Box Port 1 | ||
| Box | ||
TX+ | RX+ | ||
| |||
TX- | RX- |
| |
D+ | TX+ |
| |
D- | TX- |
| |
|
|
•Protocol Settings
Select a communication protocol for the camera.
No | Protocol |
|
| ||
1 | Samsung | OFF | OFF | OFF | OFF |
2 | OFF | OFF | OFF | ON | |
3 | OFF | OFF | ON | OFF | |
4 | Samsung Elec. | OFF | OFF | ON | ON |
5 | Panasonic | OFF | ON | OFF | OFF |
6 | Vicon | OFF | ON | OFF | ON |
7 | Honeywell | OFF | ON | ON | OFF |
8 | AD | OFF | ON | ON | ON |
9 | Reserved | ON | OFF | OFF | OFF |
10 | Reserved | ON | OFF | OFF | ON |
11 | Reserved | ON | OFF | ON | OFF |
12 | Reserved | ON | OFF | ON | ON |
13 | Reserved | ON | ON | OFF | OFF |
14 | Reserved | ON | ON | OFF | ON |
15 | Reserved | ON | ON | ON | OFF |
16 | Reserved | ON | ON | ON | ON |
※Factory Release Mode: Samsung Techwin (OFF/OFF/OFF/OFF)
•Baud Rate Settings
Select the transfer speed for a selected communication protocol.
No | Baud Rate(BPS) | ||
1 | 2,400 | ON | ON |
2 | 4,800 | ON | OFF |
3 | 9,600 | OFF | OFF |
4 | 19,200 | OFF | ON |
※Factory Release Mode: 9,600BPS
NETWORK PTZ CAMERA 16 User Guide | NETWORK PTZ CAMERA 17 User Guide |